Installation and Connection

3.2.6 Control Connections

The control connections must be made in accordance with the specification of the "CONTROL"
connector of the ADW300. Functions and typical connections are presented in
page
14. For further details on the specifications of the connector signals, refer to
7 TECHNICAL SPECIFICATIONS on page
NOTE!
For the configuration of the digital inputs, refer to the programming manual,
available for download on website: www.weg.net.
Connection to the
conveyor belt panel
a) Connections for operation via Electronic Potentiometer (E.P.)
Configuration in
open collector
Connection to the
conveyor belt panel
b) Connections for operation via Frequency Signal (FI) or via Serial (RS600 Panel)
For the correct connection of the control, use:
1. Conector Molex 6 vias 5102 com terminais Molex 5103. Utilizar cabos com bitola de 0,2 mm².
2. Wiring of the connector of the control board with shielded cable and separated from the other
wiring (power, command in 110 V / 220 Vac, etc.). If those cables must cross other cables,
it must be done in perpendicularly among them, keeping the minimum separation distance
of 5 cm (1.97 in) at the crossing point.
14 | ADW300
25.
Control Connector
1
DI1
2
DI2
3
DI3
4
DI4
5
GND
6
AI1
Control Connector
1
DI1
2
DI2
3
DI3
4
DI4
5
GND
6
AI1
Figure 3.4: (a) and (b) signals control card connector
Description
Safety switch
Decelerates E.P./ Stop
Stop
Start/Accelerate E.P.
Reference 0 V
+5 Vdc power supply (Capacity: 50 mA)
Description
Frequency input (14 Hz a 200 Hz)
NC
NC
NC
Reference 0 V
+5 Vdc power supply (Capacity: 50 mA)
Figure 3.4 on
Chapter