Increases the frequency,
parameter number and
parameter value.
Decreases the frequency,
paramete r numbe r or
parameter value.
NOTE!
The remote HMI is only necessary to set parameters of the ADW300. The whole
operation of the product must occur without the remote HMI connect.
How to connect the remote HMI:
1. With the inverter disconnected from the power supply, connect the CRS485 accessory to
the XC3 connector of the ADW300 (See
2. Connect the mini USB cable between the HMI and the CRS485 accessory (See
on page
18).
3. Energize the inverter.
4. Set the necessary parameters.
5. Disconnect the ADW300 from the power supply.
6. Disconnect the remote HMI.
Figure 4.3: Connection of the CRS485 accessory to the XC3 connector of the ADW300
Keypad (HMI) and Basic Programming
Figure 4.2: Remote HMI keys
Figure 4.3 on page
S e l e c t s ( to g g l e s) d i s p l a y
between the parameter number
and its value (position/content).
Enables/disables the inverter via
acceleration/deceleration ramp
(start/stop, according to P229).
Resets the inverter after a fault
event.
17).
XC3 connector
Figure 4.4
ADW300 | 17