WEG ADW300 User Manual page 25

Fitness drive frequency inverter
Table of Contents

Advertisement

Available languages

Available languages

Figure 4.6 on page 19
illustrates the basic navigation of the operating modes of the HMI.
It is the initial state of the HMI after its successful
power-up (without the occurrence of faults, alarms or
undervoltage)
Press key
to go to level 1 of the setting mode -
selection of parameters. Pressing any other key also
switches to setting mode
Level 1:
This is the first level of the setting mode. The parameter
number is shown on the main display
Use keys
and
to find the desired parameter
Press key
to go to level 2 of the setting mode -
change of the parameter values
Level 2:
The parameter value is shown on the main display
Use keys
and
selected parameter
Press key
to confirm the modification (save the
new value). After confirming the modification, the HMI
returns to level 1 of the setting mode
NOTE!
When the inverter is in the fault state, the main display indicates the number
of the fault in the format Fxxx. Navigation is allowed after activation of key
NOTE!
When the inverter is in the alarm state, the main display indicates the number
of the alarm in the format Axxx. The navigation is allowed after the activation of
key
; thus, the indication "A" goes to the unit of measurement display until the
situation causing the alarm is solved.
NOTE!
A list of parameters is presented in the quick reference of the parameters. For
further information about each parameter, refer to the ADW300 programming
manual.
Monitoring Mode
Setting Mode
to set the new value in the
Figure 4.6: Remote HMI operating modes
Keypad (HMI) and Basic Programming
Monitoring
Setting
level 1
Setting
level 2
.
ADW300 | 19