WEG WECM-AL80-85A2 Installation, Operation And Maintenance Manual

WEG WECM-AL80-85A2 Installation, Operation And Maintenance Manual

Advertisement

Quick Links

WECM / Emerald eZA
Installation, Operation and
Maintenance Manual

Advertisement

Table of Contents
loading

Summary of Contents for WEG WECM-AL80-85A2

  • Page 1 WECM / Emerald eZA Installation, Operation and Maintenance Manual...
  • Page 2 Therefore, we advise to make a careful and detailed study of the instructions contained herein before performing any procedures on the motor. The noncompliance with the instructions informed in this manual and others mentioned on the website www.weg.net voids the product warranty and may cause serious personal injuries and material damages. For further informa- tion or explanations, check our FAQ at www.weg.net/br/faq.
  • Page 3: General Information

    1. GENERAL INFORMATION WECM / Emerald eZA product is an Electronically Commutated Motor composed by a permanent magnet motor and a drive with features customized for commercial ventilation solutions. This Manual contains only the required information that allows qualified and trained personnel to carry out their services.
  • Page 4: Identification Labels

    Check the conditions of the motor immediately upon receipt. Where any damage is noticed, this must be reported in writing to the transportation company, and immediately communicated to the insurance company and to WEG. In this case, no installation job can be started before the detected problem has been solved.
  • Page 5 Figure 2 - USA/Canada market motor nameplate Figure 3 - Motor nameplate WECM / Emerald eZA Manual | 5...
  • Page 6: Installation

    5. INSTALLATION DANGER! Make sure the AC power supply is disconnected and protected against acciden- tal energization before starting the installation; Check the motor direction of rotation, turning it without load before it is coupled to the load; To prevent accidents, ensure that the grounding connection has been performed according to the applicable standards and that the shaft key has been securely fastened before the motor is started;...
  • Page 7 Only remove the corrosion protection grease from the shaft end and flange immediately before the motor installation. Unless specified otherwise in the purchase order, WEG motors are dynamically balanced with “half key” and without load (uncoupled). The driving elements, such as pulleys, couplings, etc., must be balanced with “half key” before they are mounted on the shaft of the motors.
  • Page 8 The motor must always be positioned so the drain hole is at the lowest position; Slinger: WECM / Emerald product in vertical shaft up mounting should be fitted with water slinger ring to prevent water ingress inside the motor. Consult WEG about this optional. ATTENTION! Motors installed outdoors or in the vertical position require the use of additional shelter to protect them from water.
  • Page 9: Power Connections

    Item 6.6 - PASSIVE POWER FACTOR CORRECTION (PFC) (OPTIONAL). WEG declares that the WECM / Emerald eZA motor line is intended to be used as a part of an end-product and thus is not an independently used machine. All cables of this product need to be internally installed into the enclosure of the final product.
  • Page 10 Occasional different behavior during the normal operation (actuation of thermal protections, noise level, vibration level, temperature and current increase) must always be assessed by qualified personnel. In case of doubt, turn off the motor immediately and contact the nearest WEG service center.
  • Page 11 The product will not go to speeds higher than the value adjusted to be the maximum speed by WEG EC Motor Speed Controller; or, case not used, the nominal Nameplate Speed; Reinstall the plastic lid to the back side of the drive cover after the adjust.
  • Page 12 Figure 6 - Product standard control switches NOTE! The standard maximum speed value is preset at WEG to be the highest value of the speed range but, can be changed by the user (see item 6.3). The product has speed memory when operating in local speed adjustment. The last speed adjusted will be kept in memory when the input power supply is removed.
  • Page 13 Notes: The DC voltage signal can be applied by an external power supply or using the built-in 10VDC source and an additional potentiometer (5kΩ to 10kΩ); b. Maximum speed adjusted (see item 6.3); Solution minimum speed (lowest value of the speed range);...
  • Page 14 On the WECM standard communication version, there are two ways to change the maximum speed value for the remote speed adjust signals: Using the product local tact buttons (only up to the maximum speed set by WEG EC Motor Speed Controller) Select local speed reference in the DIP switch number 1 (switch in ON position - see item 6.2);...
  • Page 15 6.5. EXTERNAL SPEED CONTROLLER (OPTIONAL) The running speed and the maximum speed adjust can be done using the external WEG EC Motor speed controller. Connect the control cables at the WEG EC Motor speed controller borne. Below picture gives the connection sequence.
  • Page 16 Only personnel from engineering and safety must consider the configuration of the equipment for the “Fire Mode” function; WEG strongly recommends to follow the cares and procedures above before using the WECM / Emerald eZA in the “Fire Mode” function, and it will not be liable to the final user or third parties for any losses or damages direct or indirectly incurred due to the programming and operation of the WECM / Emerald eZA in “Fire Mode”...
  • Page 17 WECM are not 'smoke extraction' motors (as defined in EN 12101-3) and may not under any circumstances be installed inside the high temperature airstream. NOTE! When the user activates the "Fire Mode" function, he/she acknowledges that the protection functions of the WECM / Emerald eZA are disabled, which may result in damages to the WECM / Emerald eZA itself, to the components connected to it, to the environment in which it is installed and to people present in such environment;...
  • Page 18 - Wait temperature automatically after or lower cooling conditions recovery Temperature temperature gets 0x04 than the minimum. - Consult WEG if this Limitation lower than the (See user manual) problem persists; limitation Recovers -Voltage supply higher than - Waiting power supplier...
  • Page 19: Maintenance

    For special applications and operating conditions refer to the manual 50033244 available in the website or contact WEG. When contacting WEG, please, have the full description of the motor at hand, as well as the Motor model, Batch Number and manufacturing date, indicated on the motor nameplate.
  • Page 20: Warranty Term

    In order for the warranty to be valid, the customer must be sure to follow the requirements of WEG’s technical documents, especially those set out in the product Installation, Operation and Maintenance Manual, as well as the applicable standards and regulations in force in each country.
  • Page 21: Standards And Directives

    11.2. STANDARDS AND DIRECTIVES WECM motors comply with the latest versions of the following standards and regulations: EN 60034-1: Rotating electrical machines - Part 1: Rating and performance EN 60034-2-1: Rotating electrical machines - Part 2-1: Standard methods for determining...
  • Page 22 WEGeuro – Industria Electrica S.A. Headquarters: WEG electric motors and components used for following motor lines: WECM – WEG Electronically Commutated Motor BLDC – Permanent Magnetic Synchronous Motor (Al) when installed, maintained and used in applications for which they were designed, and in compliance with the relevant installation standards and manufacturer’s instructions, comply with the provisions of the following...
  • Page 23 WECM / Emerald eZA Manual | 23...
  • Page 24 +55 47 3276.4000 motores@weg.net Jaraguá do Sul - SC - Brazil MOTORS Cod: 50119773 | Rev: 01 | Date (m/a): 01/2023. The values shown are subject to change without prior notice. The information contained is reference values.

This manual is also suitable for:

14634981

Table of Contents