Estimated Consumption; Tips For A Good Cup Of Coffee; Maintenance And Cleaning; Safety Precautions - Astoria Plus4YouTS SAEP Use And Maintenance Manual

Hide thumbs Also See for Plus4YouTS SAEP:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 33

6.12.10 Estimated consumption

To view the machine's consumption in kWh,
press the indicated button.
Select the
and
buttons and the weekly or monthly
data can be viewed respectively.
To return to the previous menu, press the
Estimated
Consumption
1
0.7
0.7
0.6
Thu
Fri
Sat
Sun
Days of
the week
Estimated
Consumption
20
18
17.5
16.5
17
16.5
May
Jun
Jul
Aug
Sep
Oct
Nov
'13
'13
'13
'13
'13
'13
'13
Months

6.13 Tips for a good cup of coffee

Wash the filters and filter holders on a daily basis, as indicat-
ed in para. 7.7.2 on page 61. The failure to perform this
cleaning operation will negatively affect the quality of the
dispensed coffee.
To obtain high-quality coffee, it is important that the water
hardness does not exceed 6-7°f (French degrees). If the water
hardness exceeds these values, it is advisable to use a water
filter or softener. Avoid using a water softener if the water
hardness is less than 4°f.
If the taste of chlorine in the water is particularly strong, in-
stall a special filter.
Do not to keep large amounts of coffee beans on hand. If
you change the type of coffee, we recommend calling out
the Technician to adjust the water temperature and coffee
grinder.
If the machine has not been used for a certain period of time
(2-3 hours), carry out a few dry runs. Make sure that the ma-
chine is constantly cleaned and periodic maintenance is car-
ried out.
User Manual
button.
kWh
Last week
1
0.9
0.7
Mon
Tue
Wed
Daily
Weekly
consumption
statistics
kWh
Last year
20
17
16.5
16.5
15.5
15
Dec
Jan
Feb
Mar
Apr
'13
'14
'14
'14
'14
Monthly
Monthly
consumption
statistics

7. MAINTENANCE AND CLEANING

7.1 Safety precautions

Carefully read the instructions provided in
chapter "I. SAFETY PRECAUTIONS" on page
33.

7.2 Periodic maintenance

Besides carrying out maintenance activities according to
the frequency specified in the "Periodic maintenance table",
a general inspection must be carried out on the machine at
least once a year by a Technician.
Component problems highlighted in grey require
the machine to be switched off and the Technician
to be called out.
7.3 Maintenance after a short period of
machine inactivity
"Short period of machine inactivity" refers to a period of time
exceeding one working week.
If the machine is switched back on after this period, the Tech-
nician must replace all the water inside the hydraulic circuits
as indicated in para. "7.2 Periodic maintenance".
Furthermore, all periodic maintenance operations must be
carried out, see the previous paragraph.
Component problems highlighted in grey require
the machine to be switched off and the Technician
to be called out.

7.4 Malfunctions and solutions

The machine provides the user with important messages re-
garding its operating status.
Messages regarding the alarms that may occur during opera-
tion are displayed on the bottom of the screen.
In the "Malfunctions and Solutions Table", alarms and actions
to carry out in order to try and resolve the reported problem
are provided.
Problems highlighted in grey require the machine
to be switched off and the Technician to be called
out.
If the malfunction cannot be resolved or an alarm
signal has appeared on the display, turn off the
machine off and call out the Technician.
Plus4YouTS
57
216
of

Hide quick links:

Advertisement

Table of Contents
loading