Installer Menu
The user can use the Silent Exit feature to silence the audible progress
annunciation of the exit delay.
If Silent Exit is active, the Exit Time is doubled for that exit period only but does
not exceed 255 seconds.
To specify the ex it delay :
1.
Using the numeric keypad, specify the length of time for the exit delay
between 45 and 255 seconds.
Press Enter to save your selection.
2.
6.4.2
Exit Restart
When this feature is enabled, an Exit Restart delay occurs on the second zone
opening within the same zone and the Exit Delay time is doubled. If it is
disabled, the same zone may be opened several times while in the Exit Delay
countdown. The default setting is Enabled.
6.4.3
Entry Delay
An entry delay enables the user to enter the site through a specified door
(determined as a delay zone) using a predetermined path, without setting off
an alarm. The entry delay is set at 30 seconds by default.
After entry, the user must disarm the system before the entry delay expires. A
progress annunciation of slow-rate warning beeps sound upon detection of
the specified zone. The system counts down the last 10 seconds of the delay
indication if enabled or the warning beeps become faster.
To modify the entry delay :
1.
Using the numeric keypad, specify the length of the entry delay between
30 and 240 seconds.
2.
Press Enter to save your selection.
6.4.4
Auto Arming
Auto Arming allows scheduled arming and disarming of the system for all
weekdays at different hours.
To activ ate auto arm:
Using Menu, select the day of the week.
1.
Press Enter to confirm.
2.
Using Menu, select one of the following options:
3.
Disabled
Arm Home
Arm Away
4.
Press Enter to confirm.
5.
Using the numeric keys, enter the system arming time (24 hours).
Press Enter to confirm the time.
6.