Certificate Of Suitability; What To Do If - Becker C01a Assembly And Operating Instructions Manual

Roller shutter drive with integrated radio receiver 915.3 mhz
Table of Contents

Advertisement

Tubular drive is not functioning.
Shutter direction on tubular drive cannot be set.
Incorrect shutter direction after deleting limit positions.
Tubular drive stops arbitrarily; cannot be restarted in the same
direction.
Switching times cannot be set on tubular drive.
Tubular drive does not operate at the set switching time.
Set switching times change.
During the programming run, the drive stops short of the limit
position to be programmed.
Ventilation slots of the roller shutter do not close fully.
24

Certificate of Suitability

Certificate No.: SAA181406

What to do if...?

Problem
Program new transmitter.
Bring transmitter within range of the tubular drive.
Press drive or stop button on transmitter at least 5 times in the
immediate vicinity of the tubular drive.
Insert batteries correctly or insert new batteries.
Check electrical connection.
Thermal protection switch in tubular drive has tripped. Wait until
the thermal protection switch in the tubular drive is reactivated.
Delete limit positions (see Deleting the limit positions [} 16])
and reset the shutter direction.
Change the shutter direction using the master transmitter or
the direction switch on the tubular drive.
Tubular drive has detected an increase in load. Briefly run the
curtain in the opposite direction, then continue in the desired
direction.
Tubular drive is overloaded. Use a higher-torque tubular drive.
Use transmitter with manual/auto slide switch.
Switch manual/auto slide switch to .
Switch the slide switch on one transmitter from to . If the
slide switch is already at , switch it to and back to .
Frequent 230 V AC power cuts.
Fluctuations in the 50 Hz mains frequency.
Use a "TimeControl" transmitter and set the desired switching
time there.
For safety reasons, the drive reacts sensitively to sluggishness
during the programming run, in order to prevent damage.
Briefly run curtain DOWN and subsequently UP until you reach
the upper limit position.
Delete the limit positions (see Deleting the limit positions [} 16])
and set the limit positions as per "to lower point" (Setting the
limit positions [} 14]); to this end, first programme the lower
limit position (lower point) and then the upper limit position.
Remedy