Intelligent Installation Management; Setting The Limit Positions; Upper Stop To Lower Stop; Upper Point To Lower Point - Becker C01a Assembly And Operating Instructions Manual

Roller shutter drive with integrated radio receiver 915.3 mhz
Table of Contents

Advertisement

Changing direction of rotation via master transmitter
It is only possible to change the direction of rotation if no limit position has been set.
Press the UP or DOWN button
▻ The shading solution runs in the desired direction.
► The running direction is OK.
If the shading solution runs in the wrong direction, the running direction must be changed. Proceed as follows:

Intelligent installation management

Limit position status indicator
A brief stopping and restarting indicates that no limit position has been set in that direction of movement.
Completion of installation following automatic setting of limit positions
The drive saves the limit position permanently once the upper limit position is reached 3 times in succession. Installation is then
complete. If the limit position is set above a point, this is stored permanently.

Setting the limit positions

The limit positions can only be set with the master transmitter. The shutter direction must
be correct. When setting the limit positions, the tubular drive runs in dead-man mode with
the limit position status indicator. The upper limit position must always be set first. When
setting the upper limit position, ensure that the roller shutter curtain is not pulled out of the
guide tracks.
When first installing using springs and adjusting the limit position "...to lower stop", the
barrel in the lower limit position turns approx. 1/4 of a turn further than usual. In doing so,
the tubular drive is able to automatically detect the use of anti-lifting devices or springs.
The tubular drive switches off automatically.
Attention
When operating the tubular drive without the drive adapter for obstacle detection, if using
springs a point must be set in the lower limit position.
There are 4 ways to set the limit positions:

• Upper stop to lower stop

• Upper point to lower point

• Upper stop to lower point

• Upper point to lower stop

The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times.
Upper stop to lower stop
14
First press the programming button and, within the next 3 seconds, press both the UP
and DOWN buttons for 3 seconds.
► The tubular drive acknowledges.
Check the running direction again.
Open to the permanent upper stop.
▻ The tubular drive switches off automatically.
Then close to the permanent lower stop.
▻ The tubular drive switches off automatically.
► The limit positions are now set.

Advertisement

Table of Contents
loading

This manual is also suitable for:

R12-17R20-17R30-17R40-17

Table of Contents