If the fly screen protection function is activated, obstacle detection is activated after a revolution of the barrel of approx. 140° from
the upper limit position. If the roller shutter curtain meets an opened fly screen door, the drive stops and returns to the upper limit
position.
The fly screen protection function is deactivated on delivery.
Both limit positions must be set before the fly screen protection function can be activated.
Obstacle detection is only active in conjunction with the "drive adapter for obstacle detec-
tion".
When both or individual limit positions are deleted, this set function is deleted as well.
Activating/Deactivating the fly screen protection function
This product is made of various materials which must be disposed of properly. Find out about the applicable regulations on recyc-
ling or disposal for this product in your country.
The packaging material must be disposed of properly.
These drives are maintenance-free.
Tubular drive
Model
Type
Rated torque [Nm]
Output speed [rpm]
Limit switch range
Supply voltage
Connected load [W]
Rated current consumption [A]
Mode
Degree of protection
Min. tube inside diameter [mm]
Frequency
Emission sound pressure level
[dB(A)]

Fly screen protection function

Open the shading solution to the upper limit position.
Then re-press the programming button and also the STOP and UP buttons for ap-
prox. 3 seconds.
► The tubular drive acknowledges.

Disposal

Maintenance

Technical data dia. 45

R12-17
R20-17
12
17
120
0.50
R30-17
C01a
CPROF+ A2
20
30
17
17
64 revolutions
240 V AC / 50 Hz
160
210
0.70
0.95
S2 4 min
IP 44
47
915.3 MHz
≤ 70
R40-17
40
17
260
1.10