Installation – Residential
Warning:
Under no circumstances is this heater to be installed in a makeshift or "temporary" manner.
It may be fired only after the stove is installed properly.
DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR DISTRIBUTION
DUCT.
We recommend that our woodburning hearth products be installed and serviced by
professionals who are certified in the U.S. by the National Fireplace Institute
NFI woodburning Specialists or who are certified in Canada by Wood Energy
Technical Training (WETT).
Outside combustion air or fresh air into the room may be required in your area, consult
local building codes (see Combustion Air section).
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO: IN CANADA
- ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY, IN USA
- UL-103 HT LISTED CONNECTOR AND CHIMNEY
Clearances – Residential
1.
This heater may be installed using a single-wall connector (smoke pipe) or listed double-
wall connector (see Mobile Home installation).
2. Clearances to combustible surfaces and materials using single-wall connector are shown
in Figure #2.
Clearances may be reduced with various heat insulating materials. Consult local, National
fire codes and authorities for approval.
3. Alternately, for close clearances, use a listed double-wall connector.
See Figure #2a.
Fig #2
SINGLE WALL
CONNECTOR
Fig #2a
DOUBLE WALL
CONNECTOR
190617-24 AL6B
Minimum Clearances to Combustibles – Residential
9"
12"
22"
17.75"
229mm
305mm
451mm
559mm
18"
14"
356mm
457mm
30"
28.75"
756mm
762mm
5"
7.5"
191mm
127mm
13"
14"
15"
16.25"
330mm
413mm
356mm
381mm
26"
27.75"
705mm
660mm
ALCOVE:
7
Do not connect this unit
®
(NFI) as
to a chimney flue serving
another appliance.
152mm
279mm
10"
20"
18.75"
254mm
476mm
508mm
16"
406mm
16"
406mm
30.75"
28"
781mm
711mm
Min. Height 7 feet(2.1m)
Max. Depth 4 feet(1.2m)
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
11"
6"
152mm
20.25"
25"
279mm
514mm
635mm
11"
6"
18"
4"
19.25"
5"
489mm
127mm
457mm
102mm
4"
5"
127mm
102mm