TESTED and LISTED to CAN/ULC S627 AND UL 1482 Meets the Environmental Protection Agency's July 1990 Particulate Emission Standards MODEL: SUMMIT SUMMIT CLASSIC SERIES-B 091013-20 SUMMIT-B 5055.3252...
Understanding & Operating Your Pacifi c Energy Stove ......14 may result in property damage, bodily Replacement Parts ................15 injury, or even death. Replacement Parts - Summit Classic ...........16 Pedestal or Legs Installation Instructions ..........17 Firebrick Installation Instructions ............18 Label .....................19...
. Be careful as they are very sharp. Install new glass complete with gasket. Replace frame, clamps and screws. CAUTION: - do not overtighten, tighten screws very carefully - do not clean glass when hot - do not use abrasive cleaners on glass SUMMIT-B 091013-20...
- Replace if the baffle has permanent warping greater than this or has cracking or breakage. - Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and may void your warranty SUMMIT-B 091013-20...
Proper clearances are critical during such a fi re. Chimney fi res are easy to detect; they usually involve one or more of the following: -Flames and sparks shooting out of the top of the chimney -A roaring sound -Vibration of the chimney SUMMIT-B 091013-20...
(removable cover facing up) with the holes on the stove. 2) Position the legs over top of the same holes on the stove. 3) Secure in place with 1" x 1/2" bolts previously removed. 4) Carefully place the unit in the upright position. SUMMIT-B 091013-20...
Do not connect this unit to a chimney fl ue serving another appliance. Minimum system height is 15 feet (4.6 m.) (measured from base of appliance). Double-Wall Connector Use a listed double-wall connector. Install all components to the chimney connector manufacturer's installation requirements. SUMMIT-B 091013-20...
During extremely cold weather, and especially when burning at very slow rates, the upper parts of the exposed chimney may ice up, partially blocking the fl ue gases. If blockage occurs, fl ue gases may enter living space. 16" [406mm] SUMMIT-B 091013-20...
4. After the fi re has established itself, open the door and add a few small logs. Close door. Your PACIFIC ENERGY heater is designed for maximum overall 5. Begin normal operation after a good coal base exists and wood efficiency at a moderate fi ring rate.
If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in closed container until all cinders have thoroughly cooled. Other waste should not be placed in this container. SUMMIT-B 091013-20...
1. Combustion air supply blocked - Check outside air supply for obstruction - Check that room air cover is removed 2. Draft too low - Chimney plugged or restricted, inspect and clean - Chimney oversized or otherwise unsuitable, consult Dealer SUMMIT-B 091013-20...
19 ..Pedestal Assembly ........SUMB.3147 20..Pedestal Front Cover ......SUMM.32075 21..Ash Dump Assembly ......WODC.2261 All parts may be ordered from your nearest Pacifi c Energy dealer. Contact Pacifi c Energy for the location of the dealer nearest you. DR46.XX SUMMIT-B 091013-20...
Super 27 and Pacifi c Summit Pedestal or Legs Installation Instructions Required: Pedestal Kit Leg Adapter Pedestal base Ash drawer enclosure Front cover (attached) Front cover (attached) 1/2" washers with Leg Set Legs NOTE: Optional ash dump kit should be installed prior to pedestal or leg kit assembly.
Firebrick Installation Instructions Pacifi c Summit and Summit Classic Wood Stove This package contains 17 full-size fi rebricks, as well as 7 various cut-size bricks. If your heater came with an ash cleanout system, or an optional one is being in- stalled, one brick (D) will not be needed for your installation.