Troubleshooting - Pacific energy ALDERLEA T6 Installation & Operation Manual

Hide thumbs Also See for ALDERLEA T6:
Table of Contents

Advertisement

A
A
ppendix
Problem
Glass is Dirty
Excessive Creosote Buildup
Low Heat Output
Won't Burn Overnight
Wood Won't Burn
190617-24 AL6B

Troubleshooting

Cause
1. Wood is wet
2. Turning down air control
or damper too soon
3. Draft too low
4. Door gasket leakage
See 1,2,3, above.
1. Wood is wet
2. Fire too small
3. Draft too low
1. Air control is set too high
2. Not enough wood
3. Draft too high
4. Poor quality or wet wood
1. Combustion air supply blocked
2. Draft too low
17
Cure
• Use dry wood
• Do not turn down until
a) there is a good bed of coals
b) the wood is charred
• Improper chimney height and / or
diameter, -consult dealer
• Chimney plugged or restricted,
- inspect and clean
• Provide outside air for combustion
• Replace gasket
• Check latch for proper operation
See 1,2,3, above.
• Use dry wood
• Build a larger fire
• Chimney plugged or restricted,
- inspect and clean
• Set air control lower
• Unsplit wood is preferred for
overnight burns
• Excessive chimney height and/or
diameter
• Use good quality, dry wood
• Check outside air supply for
obstruction
• Chimney plugged or restricted,
- inspect and clean
• Chimney oversized or otherwise
unsuitable, -consult Dealer
©PACIFIC ENERGY FIREPLACE