TESTED and LISTED to CAN/ULS S627 AND UL 1482 Meets the Environmental Protection Agency's May 2015 Particulate Emission Standards MODEL: SUMMIT SUMMIT CLASSIC SERIES-B 280416-24 SUMMIT-B 5055.3252...
PLEASE SAVE THESE INSTRUCTIONS This manual describes the installation and operation of the Pacific Energy, SUMMIT Freestanding wood heater. This heater meets the 2015 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold after May 15, 2015. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 11,300 to 38,500 Btu/hr.
SUPPLIED OR SPECIFIED BY MANUFACTURER WHEN DOING MAINTENANCE OR REPLACEMENTS. 4. DOOR GASKETS - The gasket used by Pacific Energy (7/8"(22mm) medium density fiberglass rope) requires only light pressure to seal. This will prolong seal life. It is important that the door seal be maintained in good condition.
- Replace if the baffle has permanent warping greater than this or has cracking or breakage. - Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and may void your warranty SUMMIT-B 280416-24...
Proper clearances are critical during such a fire. Chimney fires are easy to detect; they usually involve one or more of the following: -Flames and sparks shooting out of the top of the chimney -A roaring sound -Vibration of the chimney SUMMIT-B 280416-24...
(removable cover facing up) with the holes on the stove. 2) Position the legs over top of the same holes on the stove. 3) Secure in place with 1" x 1/2" bolts previously removed. 4) Carefully place the unit in the upright position. SUMMIT-B 280416-24...
#3, Page 7). Install all components to the connector or chimney manufacturer's installation requirements. Consult your chimney supplier for installation advice. 27 7/8" 708mm 25 1/2" 23 1/2" 648mm 597mm 8 1/2" Pacific Summit 216mm - Pedestal Model 31 1/2" 800mm 30" 762mm 27 1/2" 699mm 23 5/8"...
Page 8
(1219 mm) Non-combustible floor protector Hooded vent or * 4"(102mm) diameter air inlet with rodent screen 90 elbow turned * If the crawl space is well ventilated it is not down necessary to extend air inlet to outside SUMMIT-B 280416-24...
(0.6 m.) above highest projection within 10 feet (3 m.). The installation must meet all local codes. Do not connect this unit to a chimney flue serving another appliance. Minimum system height is 15 feet (4.6 m.) (measured from base of appliance). SUMMIT-B 280416-24...
During extremely cold weather, and especially when burning at very slow rates, the upper parts of the exposed chimney may ice up, partially blocking the flue gases. If blockage occurs, flue gases may enter living space. 16" [406mm] SUMMIT-B 280416-24...
3. Ignite the paper and leave the door ajar approimately 1/2"(13mm) - 1"(25mm) until the wood kindling is fully engulfed in flame. Your PACIFIC ENERGY heater is designed for maximum overall 4. After the kindling is fully engulfed add a few small logs. Close efficiency at a moderate firing rate.
Inspect gasket between baffle and supply tube. If necessary, in operating your heater and will obtain the performance for which replace with gasket #SUMB.31396 available from your Pacific Energy it was designed. dealer. Re-install baffle assembly in reverse order. Ensure that the...
1. Combustion air supply blocked - Check outside air supply for obstruction - Check that room air cover is removed 2. Draft too low - Chimney plugged or restricted, inspect and clean - Chimney oversized or otherwise unsuitable, consult Dealer SUMMIT-B 280416-24...
Understanding & Operating Your Pacific Energy Stove The Pacific Energy line of woodstoves is a culmination of OPERATING TIPS years of research and development. Designed to be efficient, clean-burning and user-friendly, this heater will give you years 1. Always use dry, seasoned firewood, up to 18"(457mm) long.
11b ..Side Insulation ........5068.732.C 12 ..Brick Rails (2pc. Required) ...SUMM.RAILSET 13 ..Baffle Pin ........... SSER.125001 All parts may be ordered from your nearest Pacific Energy 14 ..Baffle Gasket ........SUMB.31396 dealer. Contact Pacific Energy for the location of the dealer 15 ..
6.... Glass Clamps (4 pc.) ......SSER.1425 BN - Brushed Nickel 7.... Glass Bar Set (2 pc.) ....... SUMM.312501 All parts may be ordered from your nearest Pacific Energy 8.... Replacement Glass (c/w Tape) ..DR46.GLKIT dealer. Contact Pacific Energy for the location of the dealer 9....
Super 27 and Pacific Summit Pedestal or Legs Installation Instructions Required: Pedestal Kit Leg Adapter Pedestal base Ash drawer enclosure Front cover (attached) Front cover (attached) 1/2" washers with Leg Set Legs NOTE: Optional ash dump kit should be installed prior to pedestal or leg kit assembly.
Firebrick Installation Instructions Pacific Summit and Summit Classic Wood Stove This package contains 17 full-size firebricks, as well as 7 various cut-size bricks. If your heater came with an ash cleanout system, or an optional one is being installed, one brick (D) will not be needed for your installation.
3 Year Comprehensive Pacific Energy will replace or repair any part found to be defective (parts and labor) for three years from the date of pur- chase. This coverage includes electrical components (blowers, speed controls and thermal switches).