Pacific energy ALDERLEA T4 Installation & Operation Manual

Pacific energy ALDERLEA T4 Installation & Operation Manual

Alderlea cast iron wood stove

Advertisement

INSTALLATION & OPERATION GUIDE
ALDERLEA CAST IRON WOOD STOVE
MODELS T4, T5, T6

SAFETY NOTICE

If this stove is not properly installed, a house fi re may result. For your safety,
follow the installation instructions. Contact local building or fi re offi cials about
restrictions and installation inspection requirements in your area.
PLEASE SAVE THESE INSTRUCTIONS
TESTED and LISTED to
CAN/ULC S627 AND UL 1482
Meets the Environmental Protection Agency's
July 1990 Particulate Emission Standards
261107-28 T4-5-6
5055.202

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALDERLEA T4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pacific energy ALDERLEA T4

  • Page 1: Safety Notice

    INSTALLATION & OPERATION GUIDE ALDERLEA CAST IRON WOOD STOVE MODELS T4, T5, T6 SAFETY NOTICE If this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re offi cials about restrictions and installation inspection requirements in your area.
  • Page 2: Table Of Contents

    Blower Operation ....................18 APPENDIX A fire officials about Troubleshooting ....................19 r e s t r i c t i o n s a n d T4 Replacement Parts ..................20 installation inspection T5 Replacement Parts ..................21 T6 Replacement Parts requirements in your ..................22...
  • Page 3: Safety And Maintenance

    Replacement glass can be obtained from your dealer. Use ceramic glass only. Do not substitute with any other CAUTION: type. T4 – 16.250” x 10.5” x 5mm • do not overtighten, tighten screws very carefully T5 – 17.25” x 11.395” x 5mm •...
  • Page 4: Creosote

    Do not burn household trash, cardboard, plastics, construction lumber, treated or beach wood. (salt from beach wood will corrode your fi replace and void your warranty) Do not leave the air inlet wide-open for extended periods of time. Keep a fi re extinguisher handy. 261107-28 T4-5-6...
  • Page 5: In Case Of A Chimney Fire

    We recommend that our woodburning hearth products be installed and serviced by professionals who are certifi ed in the U.S. by the National Fireplace Institute ® (NFI) as NFI woodburning Specialists or who are certifi ed in Canada by Wood Energy Technical Training (WETT). 261107-28 T4-5-6...
  • Page 6: Appliance Dimensions

    Appliance Dimensions Fig #1 26” 20.75” MODEL T4 5.75” 28” 25” 28.5” MODEL T5 10.125” 29.11/16” 29.25” 28.75” 8.5” MODEL T6 29.13/16” 261107-28 T4-5-6...
  • Page 7: Installation - Residential

    Clearances may be reduced with various heat insulating materials. Consult local fi re codes and authorities for approval. 3. Alternately, for close clearances, use a listed double-wall connector. See Figures #2a, #2c & #2e. Fig #2 Minimum Clearances to Combustibles – Residential MODEL T4 10” 15” 11" 12" 20.75”...
  • Page 8: Minimum Clearances To Combustibles – Residential

    11" Fig #2e 4" 6” 5" 18.75” 9” 10" 18" 17.5” 14.5” 20" 15" 12” 14" 15” 16" DOUBLE WALL 24.75” 26" 15” 16" 27.75” CONNECTOR 28" 4" ALCOVE: Min. Height 7 1/2 feet Max. Depth 4 feet 261107-28 T4-5-6...
  • Page 9: Chimney And Connector

    The CEILING HEIGHT chimney must be suitably supported CHIMNEY CONNECTOR by the chimney manufacturer's listed offset support. T4 - 56 3/4” (1441 mm) T5 - 55 1/4” (1403 mm) T6 - 56 1/2” (1409 mm) 48" (1219 mm) NON-COMBUSTIBLE...
  • Page 10: Double-Wall Connector

    Use holes provided in collar to secure pipe with two screws. 5. Install the remaining lengths of pipe one on top of the other to the fi nished height of the chimney connector and secure to each other. 261107-28 T4-5-6...
  • Page 11: Installation - Mobile Home

    (see Figure #3, Page 9). Install all components to the connector or chimney manufacturer's installation requirements. Consult your chimney supplier for installation advice. Fig #4a Minimum Clearances to Combustibles – Mobile Home MODEL T4 DOUBLE WALL CONNECTOR 12” 8" 8"...
  • Page 12: Minimum Clearances To Combustibles – Mobile Home

    DOUBLE WALL CONNECTOR 8" 8" 18" 22" 16" 28" 8" Fig #4c Minimum Clearances to Combustibles – Mobile Home MODEL T6 DOUBLE WALL CONNECTOR 7” 5” 8" 8" 15.5” 18" 19.75” 22" 14” 16" 26.75” 28" 5” 8" 261107-28 T4-5-6...
  • Page 13: Listed Chimney And Chimney Connector For Mobile Home Installation

    CL48 SDP-P SDT-P 2' Chimney length T-24 HS 24 CL24 SDP-P SDT-P Roof fl ashing RF17 T-SFA 8RFFU SDP-F SDT-F Storm collar T-SC TGSC PL-ASCG SDP-SC SDT-SC Spark arrestor rain cap XCPE RCSA RCSA T-CT 6PL-MPC SDP-C SDT-C 261107-28 T4-5-6...
  • Page 14: Floor Protector

    T5 - 40” T6 - 41 1/2” T6 - 36” This protection must extend as follows: Minimum Overall Depth T4 - 43 1/4” Minimum Overall Depth T4 - 33 1/4” T5 - 50 1/2” T5 - 40 1/2” In Canada: 18" (457 mm) on the fi ring side...
  • Page 15: Operation

    Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. Your PACIFIC ENERGY heater is designed for maximum overall effi ciency at a moderate fi ring rate. Overfi ring is hazardous and a waste of fuel. Too slow a burn contributes to creosote buildup and lowers combustion effi ciency.
  • Page 16: Lighting For The First Time

    3. Use wood of different shape, diameter and length (up to 18"). Load your wood endwise (side to side with Model T4) and try to place the logs so that the air can fl ow between them. Always use dry wood.
  • Page 17: Restarting After Extended Or Overnight Burns

    Fill the cavity with the remaining ash level with the when cleaning. fi rebox fl oor. Pull out ashpan and discard ashes into metal container. Replace ashpan and ensure it is seated properly. 261107-28 T4-5-6...
  • Page 18: Disposal Of Ashes

    Manual: To manually operate the blower, set the rocker switch to "Man" and set the speed control to desired setting. This will bypass the sensing device and allow full control of the blower. Switching from "Auto" to "Man" or selecting speed may be done anytime. 261107-28 T4-5-6...
  • Page 19: Troubleshooting

    1. Combustion air supply blocked • Check outside air supply for obstruction • Check that room air cover is removed 2. Draft too low • Chimney plugged or restricted, inspect and clean • Chimney oversized or otherwise unsuitable, consult Dealer 261107-28 T4-5-6...
  • Page 20: T4 Replacement Parts

    T4 Replacement Parts #1 BAFFLE KIT ................VIST.BAFKIT #2 BRICK RAILS (2) ..............VIST.RAILSET #3 FLAME SHIELD ................VIST.2115 #4 DOOR ASSEMBLY ............. ALT4.4900MBK #5 FIREBRICK SET ............... BRIC.VISTA #6 SIDE CASTING MBK (2) ............. ALT4.4905MBK #7 TOP GRILL ASSEMBLY (3) .........ALT4.TGASSYMBK #8 ASH DUMP ASSEMBLY ............
  • Page 21: T5 Replacement Parts

    5b ...FIREBRICK - 4” x 4 1/2” x 1 1/4” (1) 22 ...DOOR STOP 5c ..FIREBRICK - 7 1/4” x 4 1/2” x 1 1/4” (1) #9 LEG CASTING (4) 5d ...FIREBRICK - 9” x 4 1/2” x 1 1/4” (16) 261107-28 T4-5-6...
  • Page 22: T6 Replacement Parts

    5b ...FIREBRICK - 4” x 4 1/2” x 1 1/4” (1) 22 ...DOOR STOP 5c ..FIREBRICK - 7 1/4” x 4 1/2” x 1 1/4” (1) #9 LEG CASTING (4) 5d ...FIREBRICK - 9” x 4 1/2” x 1 1/4” (16) 261107-28 T4-5-6...
  • Page 23: Firebrick Installation Instructions

    T4 Firebrick Installation Instructions This package contains 12 full-size fi rebricks, as well as 2 various cut bricks. If your heater came with an ash cleanout system, or an optional one is being installed, discard one full-size brick. With the heater in the upright position, install fi rebricks as follows: Install 4 full-size fi rebricks against the rear wall.
  • Page 24: Label T4

    MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMP- SON DURA-VENT MODEL DURA/PLUS AND DURA TECH. USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. • APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.
  • Page 25: Label T5

    MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMPSON DURA-VENT MODEL DURA/PLUS AND DURA TECH. USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. • OPTIONAL COMPONENTS - WATER COIL (CANADA ONLY), FAN KIT #WODC.BLOW, FAN ELECTRICAL RATING: 115V, 60HZ, 80WATTS.
  • Page 26: Label T6

    MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMP- SON DURA-VENT MODEL DURA/PLUS AND DURA TECH. USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. • OPTIONAL COMPONENTS - FAN KIT #SSER.BLOW, FAN ELECTRICAL RATING: 115V, 60HZ, 80WATTS., FRESH AIR KIT DO NOT ROUTE POWER CORD BENEATH HEATER.
  • Page 27 Notes 261107-28 T4-5-6...
  • Page 28 PACIFIC ENERGY FIREPLACE PRODUCTS LTD. Phone: 1-888-715-2398 Web site: www.pacifi cenergy.net 2975 Allenby Rd., Duncan, BC V9L 6V8 PRINTED IN CANADA...

This manual is also suitable for:

Alderlea t5Alderlea t6

Table of Contents