INSTALLATION & OPERATION GUIDE ALDERLEA CAST IRON WOOD STOVE MODELS T4, T5, T6 SAFETY NOTICE If this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re offi cials about restrictions and installation inspection requirements in your area.
Blower Operation ....................18 APPENDIX A fire officials about Troubleshooting ....................19 r e s t r i c t i o n s a n d T4 Replacement Parts ..................20 installation inspection T5 Replacement Parts ..................21 T6 Replacement Parts requirements in your ..................22...
Replacement glass can be obtained from your dealer. Use ceramic glass only. Do not substitute with any other CAUTION: type. T4 – 16.250” x 10.5” x 5mm • do not overtighten, tighten screws very carefully T5 – 17.25” x 11.395” x 5mm •...
Do not burn household trash, cardboard, plastics, construction lumber, treated or beach wood. (salt from beach wood will corrode your fi replace and void your warranty) Do not leave the air inlet wide-open for extended periods of time. Keep a fi re extinguisher handy. 261107-28 T4-5-6...
We recommend that our woodburning hearth products be installed and serviced by professionals who are certifi ed in the U.S. by the National Fireplace Institute ® (NFI) as NFI woodburning Specialists or who are certifi ed in Canada by Wood Energy Technical Training (WETT). 261107-28 T4-5-6...
Clearances may be reduced with various heat insulating materials. Consult local fi re codes and authorities for approval. 3. Alternately, for close clearances, use a listed double-wall connector. See Figures #2a, #2c & #2e. Fig #2 Minimum Clearances to Combustibles – Residential MODEL T4 10” 15” 11" 12" 20.75”...
Use holes provided in collar to secure pipe with two screws. 5. Install the remaining lengths of pipe one on top of the other to the fi nished height of the chimney connector and secure to each other. 261107-28 T4-5-6...
(see Figure #3, Page 9). Install all components to the connector or chimney manufacturer's installation requirements. Consult your chimney supplier for installation advice. Fig #4a Minimum Clearances to Combustibles – Mobile Home MODEL T4 DOUBLE WALL CONNECTOR 12” 8" 8"...
Hot while in operation. Keep children, clothing and furniture away. Contact may cause skin burns. Your PACIFIC ENERGY heater is designed for maximum overall effi ciency at a moderate fi ring rate. Overfi ring is hazardous and a waste of fuel. Too slow a burn contributes to creosote buildup and lowers combustion effi ciency.
3. Use wood of different shape, diameter and length (up to 18"). Load your wood endwise (side to side with Model T4) and try to place the logs so that the air can fl ow between them. Always use dry wood.
Fill the cavity with the remaining ash level with the when cleaning. fi rebox fl oor. Pull out ashpan and discard ashes into metal container. Replace ashpan and ensure it is seated properly. 261107-28 T4-5-6...
Manual: To manually operate the blower, set the rocker switch to "Man" and set the speed control to desired setting. This will bypass the sensing device and allow full control of the blower. Switching from "Auto" to "Man" or selecting speed may be done anytime. 261107-28 T4-5-6...
1. Combustion air supply blocked • Check outside air supply for obstruction • Check that room air cover is removed 2. Draft too low • Chimney plugged or restricted, inspect and clean • Chimney oversized or otherwise unsuitable, consult Dealer 261107-28 T4-5-6...
T4 Firebrick Installation Instructions This package contains 12 full-size fi rebricks, as well as 2 various cut bricks. If your heater came with an ash cleanout system, or an optional one is being installed, discard one full-size brick. With the heater in the upright position, install fi rebricks as follows: Install 4 full-size fi rebricks against the rear wall.
MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMP- SON DURA-VENT MODEL DURA/PLUS AND DURA TECH. USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. • APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.
MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMPSON DURA-VENT MODEL DURA/PLUS AND DURA TECH. USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. • OPTIONAL COMPONENTS - WATER COIL (CANADA ONLY), FAN KIT #WODC.BLOW, FAN ELECTRICAL RATING: 115V, 60HZ, 80WATTS.
MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMP- SON DURA-VENT MODEL DURA/PLUS AND DURA TECH. USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. • OPTIONAL COMPONENTS - FAN KIT #SSER.BLOW, FAN ELECTRICAL RATING: 115V, 60HZ, 80WATTS., FRESH AIR KIT DO NOT ROUTE POWER CORD BENEATH HEATER.