Clearances:
17
"
5/8
449mm
16
"
1/8
410mm
Figure 5: T6 Minimum clearances.
Clearances may be reduced with various heat shielding/insulating materials. Consult CSA B365 or NFPA 211
and local fire codes and authorities for approval. For close clearances, use a listed double-wall connector.
NOTE: local/national codes or regulations may override some guidelines in this manual
The services of a competent or certified installer, (certified by the Wood Energy Technical Training
program (WETT) - in Canada, Hearth Education Foundation (HEARTH) - in U.S.A.,) are strongly
recommended.
ALDERLEA T6-LE_260319-28
Residential Installation
Single Wall Connector - Residential
9"
229mm
14"
356mm
28
"
3/4
730mm
7
"
1/2
Double Wall Connector - Residential
191mm
18
5/8"
473mm
13"
16"
330mm
406mm
27
5/8"
702mm
Alcove: Min. Height 7 (2.1m)
Max. Depth 3'(914 m m)
20
1/8
511mm
6"
152mm
10"
254mm
16"
406mm
30
"
5/8
778mm
13
6"
"
152mm
19
"
1/8
5"
486mm
127mm
5"
127mm
100000087