Microcom 428LT Operator's Manual page 100

Direct thermal printer
Table of Contents

Advertisement

Chapter 5
^A
^D
Command
X
157
Takeup Motor Run Time:
The D157 command is used with optional software that controls a DC Takeup
motor instead of a cutter motor. The value for X represents how long the
takeup motor will run, in milliseconds, after printing has stopped. This
command is a volatile command with a default of 0. The ^A1^D145 command
lists the current setting under the Post Takeup Time.
0
0
1
25
2
50
3
75
4
100
5
125
6
150
7
175
8
200
9
225
10
250
11
275
12
300
13
325
14
350
15
375
16
400
17
425
18
450
19
475
20
500
21
525
22
550
23
575
24
600
25
625
X
158
Set the Dot2Gap Value:
This is the distance of the transmissive sensor, that detects diecut and blow
hole registration marks, to the dot row. This distance is set at the factory and
is typically not needed to be changed. The Dot2gap distances represent the
physical characteristics of the printer models. This command is used in
conjunction with the Finish Mode feature; see the D27 command bit position 8
for more information.
428LT Operator's Manual - 880040-0200
25 msec
Printer Commands
5-57

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 428LT and is the answer not in the manual?

Questions and answers

Table of Contents