4-5 ADJUSTING OUTPUT

-Setting the battery saving timer
Alarm output activation are limited by a timer 2 minutes.
Even if there are continuous alarm events, the alarm output
operates only once in the timer period.
Receiver
Transmitter
OFF
ON
• Alarm output:
1 output/2 minute
• D.Q. output:
1 output/2 minute
• Low battery output: 1 output/15 minutes
Caution
Remove all batteries prior to replacing with new ones.
If this is not followed, the low battery indicator LED will
not reset and continue to flicker.
-Setting the intermittent output function
When wireless configuration is being used, which is unable to
determine whether the alarm output continues, setting the
intermittent output function to the "ON" position, turns on the
intermittent alarm output.
This configures the wireless transmitter to send alarms at a specific
time intervals.
Transmitter
Receiver
OFF
ON
Intermittent Output Times
• Alarm output:
1 output/1 minute
• D.Q. output:
1 output/1 minute
• Low battery output: 1 output/5 minutes
-Setting the D.Q. output (environmental disqualification)
D.Q. will send an independent signal when the beam strength is
below acceptable levels, for more than 20 seconds, due to rain,
snow, or heavy fog.
Operating Time Chart
20 sec.
Reception level
Adverse weather
level
Alarm output level
ON
D.Q. output
OFF
2 sec.
5

OPERATION CHECK

5-1 LED INDICATION

Receiver
Alarm indicator LED
Low battery LED
DETECTOR STATUS
Power ON
Detection
(beam interruption)
Low battery power
5-2 OPERATION CHECK
After installation is complete, be sure to check the operation.
See "Setting the battery saving timer" in "4-5" to turn OFF
1
the battery saving mode.
Make sure that the alarm indicator is off.
2
If it is illuminated even when the beams are not blocked,
make optical alignment again.
Receiver
Low battery LED
Check that the low battery indicators on both transmitter and
3
receiver are OFF.
If the LED is flickering, the battery power is low.
Replace with the new batteries.
Conduct a walk test to check that the alarm indicator LED on
4
the receiver turns ON as the walker interrupts the beams.
C
Transmitter
A
Conduct a walk test and a battery check at least once a year.
5
For battery power savings, perform the operation
check before checking the following items.
(1) When installing on a wall or pole, make sure the
cover is properly attached to main unit.
(2) When installing in a beam tower, make sure the
tamper bushing is properly attached to main unit.
(See page 6 "Caution".)
-9-
Transmitter
Power LED
Low battery LED
LED Indications
The power LED turns ON.
The alarm LED turns ON.
The low battery LED flickers.
Alarm indicator LED
Receiver
Be sure to conduct a walk test
at the following three points:
B
A. In front of the transmitter
B. In front of the receiver
C. At the mid point between the
transmitter and receiver
The detector is installed
properly when the alarm
indicator LED turns ON in the
tests at all the three points.
Caution