WIRELESS DEFAULT SETTINGS (reference)

6-1 PARTS IDENTIFICATION

AX-100/200TFRi back box
A
B
N.C./N.O.
selection pins
C
Frequency band
selection pins
Connector Pins
A. Reserved
B. Reserved
C. Secondary alarm
D. T amper input
E. Reset input
F . Power
G. Ground
H. Primary alarm
Battery Common use Unit
BCU-4
+
+
+
EX
EX
* When assembling the chassis and the back box, be sure that the
wires not to get caught.
* Accessories for AX-100/200 TFRi are same as those shown on
page 2 of the enclosed AX-100/200 TFR Installation Instructions
except three cables that are already assembled and two sets of
Velcro tapes that are not used for this product.
6-2 AREA SETTINGS
< Frequency band selection pins >
Frequency can be set with the pin connector.
North America
Australia
902 – 928 MHz
915 – 925 MHz *
(Factory default)
* T o switch the frequency, insert the attached pin connector as shown above.
* For UL and ULC installations Only the North America frequency is to be used.
A
< Reset switch >
The reset switch is used when the wireless
transmitter is registered.
NOTE >>
When this switch is pressed, a wireless signal is
transmitted and the registered information is reset.
INOVONICS' wireless transmitter
EN1941
Antenna
A B C
D E F G H
Reset switch
Normal / T est switch
ON = Normal OFF = T est
* Turn it OFF when checking the low battery
signal. The low battery signal will be
continuously transmitted from EN1941.
Output voltage setting switch
Factory default ; 2.4V (OFF-ON-ON)
* Do not change to use with EN1941.
New Zealand
921 – 928 MHz *
EN1941
6-3 SIGNAL CONFIGURATION
Each event signal is transmitted as shown below in accordance
with the factory default prewiring and settings.
< AX-100/200 TFRi Receiver >
AX-100/200 TFRi
ALARM
DQ
LB
TAMPER
< AX-100/200 TFRi Transmitter >
AX-100/200 TFRi
LB
TAMPER

6-4 PRE-WIRING

C
Back box
terminal
NC
Black
COM
NO
Black
Red
+
+
C
Back box
terminal
NC
Black
COM
NO
Black
Red
+
+
-10-
EN1941
Primary alarm
Secondary alarm
Low battery
T amper
EN1941
Low battery
T amper
A
EN1941
B
BCU-4
+
EX
+
+
POWER
ALARM
DQ
LB
TAMPER
< AX-100/200TFRi Receiver >
A
EN1941
B
BCU-4
+
EX
+
+
POWER
LB
TAMPER
< AX-100/200TFRi Transmitter >