Advertisement

4-5 ADJUSTING OUTPUT

-Setting the battery saving timer
Alarm output activation are limited by a timer 2 minutes.
Even if there are continuous alarm events, the alarm output
operates only once in the timer period.
Receiver
Transmitter
OFF
ON
• Alarm output:
1 output/2 minute
• D.Q. output:
1 output/2 minute
• Low battery output: 1 output/15 minutes
Caution
Remove all batteries prior to replacing with new ones.
If this is not followed, the low battery indicator LED will
not reset and continue to flicker.
-Setting the intermittent output function
When wireless configuration is being used, which is unable to
determine whether the alarm output continues, setting the
intermittent output function to the "ON" position, turns on the
intermittent alarm output.
This configures the wireless transmitter to send alarms at a specific
time intervals.
Receiver
Transmitter
OFF
ON
Intermittent Output Times
• Alarm output:
1 output/1 minute
• D.Q. output:
1 output/1 minute
• Low battery output: 1 output/5 minutes
-Setting the D.Q. output (environmental disqualification)
D.Q. will send a trouble signal when the beam strength is below
acceptable levels, for more than 20 seconds, due to rain, snow, or
heavy fog.
Reception level
Adverse weather
level
Alarm output level
ON
D.Q. output
OFF
Wiring example when Using N.C. Transmitters
a) Sharing the D.Q. output with the alarm output
Receiver
POWER
ALARM
+
NC COM NO
Yellow
Black
Black
+
NC COM NO
POWER
TAMPER
Back box
Wiring example when Using N.C. Transmitters
b) Canceling the alarm output in adverse weather conditions
Receiver
POWER
ALARM
+
NC COM NO
Yellow-white
Yellow
Black
Black
+
NC COM NO
POWER
TAMPER
Back box
This circuit sets N.O. for a low battery output, whereas
N.C. for an alarm. Be sure to use N.O. ready wireless
transmitter for this configuration.
Turn "OFF" both battery saving timer and intermittent
output function switches when applying this wiring
example.
-10-
Operating Time Chart
2 sec.
20 sec.
DQ
LB
TAMPER
NC/NO
NC/NO
NC COM NO
Add a short-circuit wire
AWG 22 to 26
Length of about
80 mm (3 inches)
Exchange the
connections.
Tamper
Alarm
Low battery
output
output
output
Wireless transmitter
DQ
LB
TAMPER
NC/NO
NC/NO
NC COM NO
Add a short-circuit wire
AWG 22 to 26
Length of about
80 mm (3 inches)
Turn OFF switch No. 3 & 4.
Turn ON switch No. 5.
Alarm
Low battery
Tamper
output
output
output
Wireless transmitter
Caution