3.3.1.2.

Optional outputs type W (analogue)

I
+
+
+
V
Figure 17 - Analogue output connection diagram
3.3.1.3.

Optional outputs type R (relays)

I
V
Figure 18 - Relay output connection diagram
3.3.2.

J2 connector - outputs 9 and 10 (relay type)

Outputs 9 and 10 are 2 relay outputs with changeover contact (C - NC - NO).
For technical specifications, see the Technical Data.
Use cables with a cross-section of 0.25...2.5 mm2 (23-14 AWG) terminated with ferrules for connection.
2
O5
3
O6
4
O7
5
O8
1
Com 5...8
1
Com 5...8
2
Ir
O5
3
O6
4
O7
5
O8
81900A "MHW_GPC-40/600A"_03-2021_ENG_page 25
PIN
Name
1
Com 5-8
2
O5
3
O6
4
O7
5
O8
Option W includes 3 analogue 12-bit outputs configurable
via software in:
Voltage 0...10 V
Voltage 2...10 V
Current 0...20 mA
Current 4...20 mA (default)
PIN
Name
1
Com 5-8
2
O5
3
O6
4
O7
5
O8
Option R includes 4 NO relay outputs with a single com-
mon.
Description
Common outputs
Output 5 (+)
Output 6 (+)
Output 7 (+)
Not used
Description
Common outputs
Output 5
Output 6
Output 7
Output 8