Error Message
Mug Sensor SureVend Error Mug sensor blocked
Dispense Head Not Homed
Dispense Head Not
Extended
Dispense Head Motor Not
Enabled
Brewer Jam
Brewer Waste Pail Full
Brewer Jam (CoEx®)
Water filter replacement
required
Water Tank Leak
Low Water
Fault Description
since boot up.
Dispense head home
operation failed.
Dispense head extend
operation failed.
Dispense head unable to
move at all.
Unable to detect switch
input in the given time
out for Oltre paperless
brewer
Brewer waste capacity is
exceeded.
Error while operating the
CoEx® brewer.
Overall water filter usage
has exceeded the set
limit. Water filter needs
to be changed.
Main Boiler is
experiencing water
leakage.
Main boiler is running
low on water.
123
Additional information
If there is nothing present in the cup station.
Then, either the mug sensors are misaligned or
sensors are faulty. The machine will be taken
out of service if this error occurs. This error will
be cleared once the above mentioned issues
are fixed.
Machine will be taken out of service, as the
machine can no longer dispense a drink. This
error is normally a result of faulty home switch
or motor
Machine will be taken out of service as it can
no longer dispense any more drinks. This error
is normally a result of faulty opto sensor or
motor
If the software is unable to detect any activity
on opto sensor then it will raise this error. The
error can be down to faulty motor or faulty
opto sensor.
This will disable all brewer drinks for this
particular brewer.
This error will only be raised if brewer waste
management is enabled. It will disable all fresh
brew drinks. The drinks will only be enabled
after the counters are reset from the service
menus.
Motor is stalled or is taking more current than
the allowed limit or switch not being activated.
This error is only raised if water filter counters
are enabled. Once the error is raised no further
drinks could be taken until the counter is reset
from service menus.
This error is raised if the main boiler requests
fill operation 15 times even though none of the
valves attached to it were operated.
This error will be cleared once main boiler is
filled up.