Commissioning Procedure - CPI COTI Technical Manual

Table of Contents

Advertisement

Technical Manual
SERVICE NOTE
Battery Backup
The battery backup located on the Atlas H Board (back side of the
board) is used to maintain the date and time in case of power
interruptions or any time the main power is off.
Important: If any internal fuses become damaged or fail in any way, they must be
replaced with the correct fuse available from the manufacturer quoting the
information written on the label adjacent to the relevant fuse holder.
Important: If the power cord becomes damaged in any way it must only be replaced
with one obtained from Crane Merchandising Systems.

2.4 Commissioning Procedure

A trained installation engineer must carry out the following procedure before the machine
can be used for the first time. Ensure that the electrical and water services to the machine
are connected correctly. Check for leaks in the water supply.
Open the front door of your machine.
Ensure that any waste buckets/trays are fitted correctly. On COTI machines, clip the level
probe and overflow pipes correctly onto the rim of the bucket.
Cup Turret (COTI Machines)
Note: Before filling with cups, check the scrolls on the cup drop unit are set correctly for
the size of cups used, refer to section 2.5. Fill with the correct size cups for the cup catcher
fitted to the machine. Allow the cups to drop into the tubes directly from the packaging.
DO NOT touch the cups with your hands.
Important: Do not fill the tube directly above the cup dispense position. Allow the cup
turret motor to rotate a full tube to the cup dispense position. Rotating the cup turret by
hand will damage the mechanism.
Note: If you are using paper cups, first inspect each sleeve for damage to the cup rims.
Damaged cups must not be used.
On powering on the machine the cup turret mechanism will index the first stack of
available cups to the dispense position and drop the cup stack into the cup drop
mechanism. Fill the remaining empty cup stacks with cups and replace the lid.
All Models: The water inlet valve will open and the heater tank will start to fill. As the
water heats, ensure that no water overflows from the heater tank overflow pipe into the
waste bucket/tray. Check the system for leaks.
All Models: As heater tank fills and heats, ensure that no water overflows from overflow
pipe into the waste pail / tray.
Note: The machine has a safety cut-out which will only allow the heater tank to fill for a
maximum of two minutes. If after power-up the heater tank has not filled within this time,
the door switch should be cycled to reset the heater tank time-out.
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linea

Table of Contents