Diagnosis And Troubleshooting; Remove The Battery; No Signal To Diagnostic Tool - Husqvarna 536LiL Workshop Manual

Hide thumbs Also See for 536LiL:
Table of Contents

Advertisement

6 Diagnosis and troubleshooting

6.1 Remove the battery

Press in the catches and remove the battery.
See figure 1.
WARNING!
The battery must always be removed
for service/repair work and may only
be replaced once the trimmer has
been completely assembled again!
WARNING!
Do not short circuit the battery!
Never unscrew the battery!
Never fit a damaged battery!
Replace a damaged battery!
6.2 Connect diagnostic tool - LiL /
LiLX / LiR / LiRX
1
Connect the adapter cable for the diagnostic tool to
the battery and the battery contact on the trimmer.
Connect cable (A) to the diagnostic tool for trouble-
shooting the trimmer.
Connect cable (B) to the diagnostic tool for trouble-
shooting the battery.
NB! Refer to the manual for the Diagnostic Tool
Battery for detailed instructions and follow the
instructions in the diagnostic tool.
See figure 2
2
Diagnose/troubleshoot according to the diagnostic
tool instructions and make any necessary repairs
as instructed in the relevant chapter in this manual.

6.3 No signal to diagnostic tool

1
Check that the contact on the battery and the bat-
tery contact on the trimmer are intact and clean.
Replace the battery or control unit on the trimmer
respectively if there is any damage.
2
Check that the cable to the diagnostic tool is intact
and clean. Replace the cable if it is damaged.
3
Restart the computer/Reinstall the software.
Diagnosis and troubleshooting
1
2
Fig 1
A
Fig 2
1
B
– 23
English