Standard Service Menus

R40 Standard Service Menus

R40 Standard Service Menus
The Standard Service Menus include the Hardware Validation, Information, and My Set-
tings service menus.
TIP: To learn additional information about the R40 console standard service menus,
refer to the
TRM445 Owners Manual

Hardware Validation (51765761)

Service Access Code: 51765761 (see
The Hardware Validation menu provides a set of automated hardware diagnostic tests and
calibration procedures used to troubleshoot, calibrate, and verify machine operation. The
diagnostic tests are customized for the particular equipment type and console configuration.
How to run a test
Select Test to start the test, follow prompts to execute the test, and select Stop Test to exit.
Hardware Validation diagnostic tests
DIAGNOSTIC TEST
Display GUI/Metric
Test
KEY Test
Heart Rate Test
Belt Speed Test
Incline Test
1
analog to digital converter
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
, see
"" on
page 26)
Test console LED lights and backlight:
Backlight brightness changes
o
Numerals cycle properly
o
Test hard keys.
Heart rate is acquired and displayed.
Running belt moves and is controlled from 0.5 mph to 12.0 mph
in 0.1 increments.
Use controls to raise/lower incline to verify the following incline
1
angle
A/D
values:
Nominal value: 13 ±5 @ -2% incline
l
Nominal value: 37 ±5 @0% incline
l
Owners Manual
TEST DESCRIPTION
4 Standard Service Menus
Standard Service Menus
.
Page 29