Installation
1. Hold the LPCA in the mounting position but do not install into the mounting screws.
Then reconnect the LPCA I/O cable connections: It is easier to make LPCA I/O con-
nections before securing the LPCA into the mounting screws. Be careful not to dam-
age the LPCA connectors. Reconnect the following LPCA cable connections:
Drive Motor power cable, red (M7) and black (M8), connectors to the drive
l
motor.
AC input blue wire (M1) and brown wire M2) cable connectors.
l
Two lift motor connections: the Lift Drive (J1) connector and the Lift Pot (J8)
l
connector.
Safety Breaker (J2) connector.
l
Speed sensor (J3) connection.
l
Comm Cable (J6) connection.
l
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.