DIAGNOSTIC TEST
Beeper Test
Keypad Test
LCD Test
Heart Rate Test
Belt Speed Test
Incline Test

Information Display (65)

Service Access Code: 65 (see
The Information Display provides the equipment usage information, software pn/version
information, and Error Log access.
INFORMATION DISPLAY
ODOMETER
HOUR METER
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Beeper sounds once every second.
Press all hard keys and verify change to the pattern. The test will
exit when all keys have been pressed. Pressing down Workouts
for 5 seconds also exits the test.
Test will light up all segments and sections of the display.
Heart rate is acquired and displayed.
Menu: Machine Test > Belt Speed Test
Range: 0.5 mph to 12.0 mph in 0.1 increments.
Press Go to start the Belt Speed Test (IMPORTANT the
l
running belt will start movint).
Use the SPEED control to very speed.
l
Use controls to raise/lower incline to verify the following incline
angle A/D values:
Nominal value: 13 ±5 @ -2% incline
l
Nominal value: 37 ±5 @0% incline
l
Nominal value: 242 ±5 @ 15% incline
l
"R20 How To Access Standard Service menus" on
The total number of accumulated miles (or kilometers) on
the unit.
This value is stored in the upper PCA in the console so if
the PCA is replaced the accumulated miles would start
again from "0".
The total number of hours that the unit took to accumulate
unit miles.
This value is stored in the upper PCA in the console so if
that PCA is replaced the hours of use would start again
from "0".
TEST DESCRIPTION
DESCRIPTION
4 Standard Service Menus
Information Display (65)
page 28)