9.3 Debug Operations

9.3.4 Operation Mode

Using the operation mode function makes it possible to prevent some debug operations from
being executed. This can prevent incorrect operation of the GM1 controller when it is operated
accidentally.
The current operation mode is displayed as an icon on the status bar.
Debug (
)
This mode has no restriction.
Locked (
)
Start / stop, new breakpoint setting, and forcing values cannot be executed.
Single cycle operation, writing variables, and unforcing values can be executed.
Operational ( )
Only writing variables can be executed. Start / stop, new breakpoint setting, forced variable
change, single cycle, and canceling forced variable change cannot be executed. To use this
mode, the following conditions must be satisfied.
● Application is running
● There is no active breakpoint
● There is no variable whose value has been forcibly changed
● The application created in GM Programmer matches the boot application in the GM1
controller
1.
After logging in, from the menu bar, select Online>Operation Mode>Locked.
The operation mode will be changed from Debug mode to Locked mode.