Connecting The Gm1; Flow Of Operation Check - Panasonic GM1 User Manual

Motion controller controller rtex
Hide thumbs Also See for GM1:
Table of Contents

Advertisement

8.1 Flow of Operation Check

8.1 Flow of Operation Check
This chapter explains how to connect the PC where GM Programmer is installed and the GM1
controller and operate the GM1 controller from the PC.
First, this section explains the flow of operation check for a program that is created.
1.
Build
Execute build to check a program that is created. If an error occurs, correct the program and
execute build again. If code generation is executed after build is completed normally, an
application will be generated.
Operation: From the menu bar, select Build>Build. From the menu bar, select Build>Generate
Code.
2.
Connecting to the GM1 controller
Connect the PC where GM Programmer is installed to the GM1 controller.
Operation: Double-click the Device object in the navigator pane to display the "Communication
Settings" window, and then select the "Network Scan" tab and select the GM1 controller to
which you want to connect.
3.
Login
Log in to the GM1 controller. When you log in to the GM1 controller, applications are
downloaded to the GM1 controller.
Operation: From the menu bar, select Online>Login.
4.
Debug
Execute the application and perform debugging. If there are any problems with behaviors, log
out of the GM1 controller, correct the problem, and execute build again.
Operation: From the menu bar, select "Debug" and then each debug menu item.
8-2
WUME-GM1RTXOP-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gm1 series

Table of Contents