Power Supplies - Aruba 6300F Series Installation And Getting Started Manual

Table of Contents

Advertisement

Fan Condition
2 fans functioning
normally
1 fan fault
2 fans fault
System with no fan tray
Missing both fan
tray/all fans faulted
Fan redundancy refers to fans and not fan trays. With 2 fan trays installed, it allows 1 fan fault. With 1 fan tray,
there is no fan redundancy.
Fan tray with faulty fan/fans must be replaced with Aruba 6300M Fan Tray (JL669A).
For JL658A, JL659A, and JL762A:
Fan Condition
4 fans functioning
normally
1 fan fault
More than 1 fan
fault
Missing any fan
tray/all fans faulted

Power supplies

The following power supplies can be installed in the 6300M switches:
Aruba X371 12VDC 250W 100-240VAC Power Supply (JL085A): A 250 watt power supply for the
n
non-PoE switches. This power supply does not provide any PoE power, and is keyed so that it will not fit
into the power supply slots of Aruba PoE switches.
Aruba X371 12VDC 250W 100-240VAC Power-to-Port Power Supply (JL760A): A 250 watt and
n
back-to-front fan flow power supply for the non-PoE switches. This power supply does not provide any
PoE power and is keyed so that it will not fit into the power supply slots of Aruba PoE switches.
JL760A is for use only in the JL762A switch. This is the only power supply available for the JL762A
switch.
Aruba 6300F/M Switch Series Installation and Getting Started Guide | (xxxx Switch Series)
Fan Speed
According to ambient and
component temperature
Remaining fans will spin at Max
speed
N/A
N/A
Fan Speed
Accordingly to ambient and
component temperature
Remaining fans will spin with
Max speed
Remaining fans will spin with
Max speed
N/A
Fan Redundancy
Shutdown
Not supported
Component hits thermal limit
Not supported
Upon detection, system will be
shut down in 3 minutes or
component hits thermal limit
Not supported
Upon detection, system will be
shut down in 3 minutes or
component hits thermal limit
Not supported
Upon detection, system will be
shut down in 3 minutes or
component hits thermal limit.
Fan Redundancy
Shutdown
N+1
Component hits thermal limit
Not supported
Component hits thermal limit
Not supported
Upon detection, system will be
shut down in 3 minutes or
component hits thermal limit.
Not supported
Upon detection, system will be
shut down in 3 minutes or
component hits thermal limit.