Back of the switches

Figure 1 Back of the 6300M Switch
Table 7: Back of the 6300 Switch: Label and Description
Label
1
Fan tray 1 & 2
2
Power supply slot 1 & 2

Fan requirements

Switches
JL658A
JL659A
JL663A
JL664A
JL660A
JL661A
JL662A
JL762A
For JL660A, JL661A, JL662A, JL663A, and JL664A:
Fan Condition
Fan Speed
System installed with 2 fan trays
4 fans functioning
According to ambient and
normally
component temperature
1 fan fault
Remaining fans will spin at Max
speed
More than 1 fan
Remaining fans will spin at Max
fault
speed
System installed with 1 fan tray
Description
Fan Tray 1
Required
Required
Required
Required
Required
Required
Required
Required
Fan Redundancy
N+1
Not supported
Not supported
Fan Tray 2
Required
Required
Optional
Optional
Optional
Optional
Optional
Required
Shutdown
Component hits thermal limit
Component hits thermal limit
Upon detection, system will be
shut down in 3 minutes or
component hits thermal limit
Introducing the switches
|