Problem: Engraver will not power up. Nothing transpires when engraver is turned on.
Solution:
1)
Verify there is power being supplied to the engraver, that your outlet is in good working condition
and that the engraver is actually plugged in.
2)
Check to make sure the carriage can be moved freely with the power off. If the engraver can't find
the home position, it will not power up properly.
Problem: Poor engraving quality.
Solution:
1)
If you feel you are not getting the depth that you once were, this is probably a maintenance issue.
See the maintenance section (Section 7) for instructions on cleaning the optics. If you are not sure
of the location of all of your mirrors, contact Epilog.
2)
If you are experiencing a blurry or erratic image, check to make sure you are in focus and all optics
are clean.
3)
If you are experiencing a double image problem or any other quality issue, it is best to run a sample
of what the machine is doing and send it to Epilog attention Technical Support. Please include a
letter stating the configuration of your machine along with speed and power settings of the sample
you ran and any other pertinent information.
Problem: Image at the wrong location on the work piece.
Solution:
1) Verify that the page size in Corel does not exceed the maximum engravable area of the machine.
2) Verify that the page size in Corel matches the piece size in
Print Setup. If you have a page size of 2"X3" and a piece size in Print Setup of 24 X 18", then it will
place the 2 X 3" in the center of the 24 X 18" area.
3) If you see that the image is constantly off in one direction, you will need to reset the "home position"
on the machine. Please call technical support for instructions.
Problem: LCD display is malfunctioning.
Solution:
Verify that the engraver is still engraving. If the engraver is still operating, shut the engraver off and
verify the ribbon cable is connected to the LCD display on the backside of the display. If the ribbon
cable is properly connected, then contact Epilog for replacement.
Problem: Fan Malfunction.
Solution:
1) Verify that there is nothing obstructing the rotation of the fan.
2) Verify the fan is clean. Using a vacuum should clean the fan adequately.
3) Verify the connector is still connected.
4) If need be contact Epilog for replacement.
Problem: Table will not move.
Solution:
1) Verify that there is nothing obstructing the travel of the table.
2) Attempt to manual focus by pushing the Focus button and turn the round knob.
3) If you are still experiencing problems, contact Epilog Technical Support.