Alarm
Alarm ID
PLD
65544
VOLTAGE
ALARM 2P5V
(2.5 Volt Rail)
PLD
65545
VOLTAGE
ALARM 3P3V
(3.3 Volt Rail)
PLD
65546
VOLTAGE
ALARM 5V
(5 Volt Rail)
PLD
65547
VOLTAGE
ALARM CPU
(Host Voltage)
NIU Alarms
The following table lists the NIU alarms. PHY0 and PHY1 are both located on the
same NIU. PHY0 encompasses S0P0 and S0P1, while PHY1 encompasses S1P0 and
S1P1. Therefore, both insertion and both removal alarms will be activated at the same
time when the NIU is inserted or removed from the Acme Packet 4600.
Alarm
Alarm ID
PHY0 Removed
65550
PHY0 Inserted
65552
Alarm
Cause(s)
Severity
MINOR
A PLD
exceeds a
EMERGENCY
predetermined
threshold
MINOR
A PLD
exceeds a
EMERGENCY
predetermined
threshold
MINOR
A PLD
exceeds a
EMERGENCY
predetermined
threshold
MINOR
A PLD
exceeds a
EMERGENCY
predetermined
threshold
Alarm Severity
Cause(s)
MAJOR
NIU S0Px was
removed
MAJOR
NIU S0Px was
inserted
Chapter 6
Alarms
Log Message Graphic
Display
Window
Message
Voltage 2.5V
X HW
CPU has
ALARMS:
minor alarm
(where X is
the number of
Voltage 2.5V
hardware
CPU has
alarms
emergency
alarm, the
system should
shut down
Voltage 3.3V
X HW
has minor
ALARMS:
alarm
(where X is
the number of
Voltage 3.3V
hardware
has
alarms
emergency
alarm, the
system should
shut down
Voltage 5V
X HW
has minor
ALARMS:
alarm
(where X is
the number of
Voltage 5V
hardware
has
alarms
emergency
alarm, the
system should
shut down
Voltage CPU
X HW
has minor
ALARMS:
alarm
(where X is
the number of
Voltage CPU
hardware
has
alarms
emergency
alarm, the
system should
shut down
Log Message
Physical interface
card 0 has been
removed
None
6-36