Alarm Name
Alarm ID
TEMPERATU
65538
RE HIGH
If this alarm occurs, the Acme Packet 4600 turns the fan speed up to the fastest possible
speed.
Fan Speed Alarms
The following table lists the fan speed alarm.
Alarm Name
Alarm ID
FAN
65537
STOPPED
If this alarm occurs, the Acme Packet 4600 turns the fan speed up to the fastest possible
speed.
Environmental Sensor Alarm
The following table lists the environmental sensor alarm.
Alarm
Causes
Severity
CRITICAL:
Fans are
>105°C
obstructed or
stopped. The
MAJOR:
room is
>100°C
abnormally
MINOR:
hot.
>95°C
Alarm
Causes
Severity
CRITICAL:
Fan failure.
any fan speed
is <50%. Or
speed of two
or more fans
is >50% and
<75%.
MAJOR:
speed of two
or more fans
is
> 75% and <
90%. Or
speed of one
fan is >50%
and <75% and
the other two
fans are at
normal speed.
MINOR:
speed of one
fan> 75% and
<90%, the
other two fans
are at normal
speed
Chapter 6
Alarms
Example Log
Graphic
Message
Display
Window
Message
Temperature:
Temperature X
XX.XXC
C (where X is
the
(where XX.XX
temperature in
is the
degrees)
temperature in
degrees)
Example Log
Graphic
Message
Display
Window
Message
Fan speed:
Fan stopped
XXXX XXXX
XXXX
where xxxx
xxxx xxxx is
the revolutions
per minute
(RPM) of each
fan on the fan
module
6-34