Validating the SSD

Oracle recommends that you validate the Solid State Drive installation by running
Acme Packet Session Director diagnostics. All versions from nnCX_diags110.gz
and later include the appropriate tests for validating the SSD. Please refer to the
diagnostics documentation for more information. In the following procedure, after
booting into diagnostics, this preliminary check ensures that the system recognizes
the Solid State Drive.
Password: ******
-> dc
/boot/
243 MB
/code/
245 MB
/sata/
476940 MB
Starting Diagnostic Executive...
Comm Express MCH 945 Present.
AHCI Support is Enabled.
Acme Packet Net-Net 4600
Diagnostic Executive Version 1.10
Creation date: Nov 25 2014 11:08:02
Board Level Diagnostics
Date & Time: TUE NOV 25 14:56:01 2014
[diag_proc] ->

Formatting the SSD

After installing the Solid State Drive, you must format it. Details on file system designs
and the formatting procedure may be found in Chapter 9, File System Maintenance of
the Maintenance and Troubleshooting Guide for your software release.

Fan and Air Filter Maintenance

This section explains how to remove a fan and replace the air filter on your Acme
Packet 4600.

Removing and Replacing Individual Fans

The individual fan is a user-serviceable, hot-swappable component. There are five
individual fans in the Acme Packet 4600. If the Acme Packet 4600 experiences a fan
malfunction, you must remove the existing fan and replace it with a functional one.
- Volume is OK
- Volume is OK
- Drive Present
Chapter 6
Fan and Air Filter Maintenance