9.
Tighten the earth (ground) terminal connection to a torque of 2.13 Nm to 2.8 Nm.
10.
Tighten the dome shaped nut on the cable-gland until the outer sheath of the
cable is firmly gripped. Using a tool this should be tightened to a torque of 2.5 Nm,
do not overtighten.
11.
Check that the cable connections are correct, then refit the cover on the motor
terminal-box.

4.6.2 Amphenol version single-phase motors

When selecting the mating half of the amphenol connector, please ensure that it is
compatible.
The protective earth (ground) connection is required to make first and break last with
respect to the other connections.
Connect the electrical supply cable to the appropriate pins as shown in
phase motors with Amphenol connector: 220-240 V 50 Hz and 230-240 V 60 Hz on page
25.
4.6.3 110/200-240 V 50 Hz or 115-120/200-230 V 60 Hz single-phase motors
The motor is designed for a single-phase electrical supply and is suitable for 50 Hz and
60 Hz operation. The motor can be manually switched between nominal supply voltages
of 110-120 V and 200-240 V.
Use the following procedure to check that the voltage selector switch is correctly
positioned for the electrical supply voltage:
1.
Refer to
Hz and 115-120/200-240 V 60 Hz on page
terminal box cover and remove the cover.
2.
Check the position of the voltage selector switch. If the switch is in the correct
position, continue at step 3. If the voltage selector switch is in the wrong position,
press the switch to select the alternative position.
3.
Refit the terminal box cover and secure with the three screws.
When selecting the mating half of the connector, please ensure that it is compatible
(IEC60320 C19 female).
A34310880_T - Installation
Figure: Single-phase motors: 100 V 50 Hz, 100-105 V 60 Hz and 115 V 60 Hz on
page 24
Figure: Single-phase motors: 200 V 50 Hz, 200-210 V 60 Hz and 230 V 60 Hz on
page
25.
Figure: Motor voltage selection: single-phase motors, 110/200-240 V 50
26. Undo the three screws securing the