Standard Single-Phase Motors - Edwards E1M18 Instruction Manual

Rotary vacuum pumps
Hide thumbs Also See for E1M18:
Table of Contents

Advertisement

The diameter of the outer sheath of the electrical supply cable must be within the range
7 mm to 10.5 mm. The cable must conform in size and colour coding with the local and
national electrical installation regulations. The temperature rating of the cable must be
70 °C or greater.
Table 10 Motor connection details
Pump item number
A36315903, A34315903
A34315981, A36315981
A34315904, A36315904
A34316903
A34317984, A36317984,
A34317984, A36317984

4.6.1 Standard single-phase motors

1.
Remove the cover from the motor terminal box
on page
2.
Remove the cable-gland from the inside of the terminal-box and fit the cable-gland
to the cable lead-through hole in the side of the terminal-box. Using a tool this
should be tightened to a torque of 3.75 Nm.
3.
Pass the electrical supply cable through the gland.
4.
Remove the receptacle connectors from the fitting pack.
5.
Fit a ring connector to the earth (ground) wire.
6.
Select the correct size of receptacle connectors for the cable wires:
7.
Attach the appropriate connector to the live and neutral wires.
8.
Connect the electrical supply cable to the appropriate terminals as shown in:
A34310880_T - Installation
Voltage
(V)
(all)
115
230
100
100 - 105
200
200 - 210
(all)
(all)
11).
Use the red connectors for wire sizes 0.75 mm
Use the blue connectors for wire sizes 1. 5 mm
Figure: Three-phase motors: 200-220 V 50 Hz and 200-230 V 60 Hz on page 28
Frequency
Connection details:
refer to Figure
(Hz)
50/60
Figure: Three-phase motors: 200-220 V
50 Hz and 200-230 V 60 Hz on page 28
60
Figure: Single-phase motors: 100 V 50
Hz, 100-105 V 60 Hz and 115 V 60 Hz on
page 24
60
Figure: Single-phase motors: 200 V 50
Hz, 200-210 V 60 Hz and 230 V 60 Hz on
page 25
50
Figure: Single-phase motors: 100 V 50
Hz, 100-105 V 60 Hz and 115 V 60 Hz on
60
page 24
50
Figure: Single-phase motors: 200 V 50
Hz, 200-210 V 60 Hz and 230 V 60 Hz on
60
page 25
50/60
Figure: Single-phase motors with
Amphenol connector: 220-240 V 50 Hz
and 230-240 V 60 Hz on page 25
50/60
Figure: Motor voltage selection: single-
phase motors, 110/200-240 V 50 Hz and
115-120/200-240 V 60 Hz on page 26
(Figure: General view of the pump
Page 22
2
2
to 1.5 mm
.
2
2
to 2.5 mm
.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents