Replacing the
The tubes that pump waste material from the roller waste collector and the 
Waste-Pump
purge unit should be replaced after 800 hours of use. After this time, a 
Tubes
counter displays a maintenance alert on the printer interface screen. 
Figure 4-127 Maintenance alert
You can check when the pump tubes need to be replaced in the Maintenance 
Counters interface. 
To open the Maintenance Counters interface:
➢  Click on the "Maintenance Required" indicator.
or—
➢  From the Options menu, select Maintenance Counters.
Figure 4-128 Selecting Maintenance Counters from the Options menu.
When the Maintenance Counters screen opens, scroll down to the General
Pumps section.
Figure 4-129 Pump Maintenance Counters
The waste-pump tubes that require replacing are displayed in red.
Note: If the check box on the right is selected, the "Maintenance Required"
indicator appears when that task is due.