Serial Signals
Serial signals are much like analog signals, in that they, too, contain 16 bits of
information. However, whereas the value of an analog signal is used directly–to
control volume or temperature, for instance–the value of the serial signal is used as a
pointer to a location in memory that contains a string of characters. When a serial
signal is routed to a symbol, that symbol can identify the signal as serial rather than
analog and it will automatically look at the data to which it points.
Thus, serial signals are used to facilitate the transmission of serial data (strings of
characters). These signals can be generated by incoming data on a COM port or by a
symbol that has a serial output.
STX-1700CXPW Input/Output Signals
The STX-1700CXPW symbol provides up to 4000 digital joins, up to 1024 analog
joins, and up to 127 serial output joins and 255 serial input joins. The programmer
selects the signal types by clicking on the appropriate button at the top of the Symbol
Detail view when programming the panel.
The following tables list functional descriptions for touchpanel outputs and inputs.
Digital Output Signal Descriptions
OUTPUT
press 1 through press 4000
Digital Input Signal Descriptions
INPUT
fb 1 through fb 4000
Analog Output Signal Descriptions
OUTPUT
an_act 1 through an_act 1024
Analog Input Signal Descriptions
INPUT
an_fb 1 through an_fb 1024
Serial Output Signal Descriptions
OUTPUT
text-I1 through text-I127
Serial Input Signal Descriptions
INPUT
text-o1 through text-o255
Wall Mount 2-Way RF Wireless Touchpanel: STX-1700CXPW • 23
DESCRIPTION
Notifies control system of button press (1 – 4000).
High/1 = press On
Low/0 = press Off
DESCRIPTION
Notifies panel to display feedback (1 – 4000). This can
represent that the button was pressed, or can be actual
device feedback, e.g., that power was turned on.
DESCRIPTION
Notifies control system of an analog action (1 – 1024).
Any value from 0 through 65535
DESCRIPTION
Notifies panel of analog feedback (1 – 1024).
Any value from 0 through 65535
DESCRIPTION
Internal text (1 – 127) that can be remapped to system
reserved joins.
DESCRIPTION
Notifies panel to display text string (1 – 255). Also
called indirect text.