Wall Mount 2-Way RF Wireless Touchpanel
20 • Wall Mount 2-Way RF Wireless Touchpanel: STX-1700CXPW
C2Net-Device Slot in Configuration Manager
To incorporate an STX-1700CXPW into the system and have it operate either as a
wired Cresnet device (in the wall-mount docking assembly) or as a wireless RF
device (when undocked), the program needs to be designed for a dual configuration:
For a wired configuration, a back box/docking assembly (BB/DA-
1700CW) is required in addition to the touchpanel, to allow for the
electronic docking functions, touchpanel power, and Cresnet
communication.
For a wireless configuration, a gateway device (TPS-RFGWX) is
required to allow Cresnet communication between the touchpanel and
the control system. Once the gateway is configured in the C2Net-
Device Slot, the slot allows Cresnet communication.
NOTE: SIMPL Windows distinguishes between the STX-1700CXP (Cresnet) wired
version, and the STX-1700CXP wireless version of the touchpanel for programming
purposes. Although functionally identical, they are not interchangeable.
In Configuration Manager, drag the STX-1700CXP (Cresnet) icon from the
Touchpanels (Cresnet) folder of the Device Library and drop it in the upper pane of
the System Views. The System Views upper pane displays the STX-1700CXP device
icon below the PRO2 graphic.
Drag the BB/DA-1700CW from the Cresnet Control Modules | Cresnet I/O Control
& Other Modules folder and drop it in the upper pane of the System Views. The
System Views upper pane displays the BB/DA-1700CW device icon below the PRO2
graphic.
Drag the TPS-RFGWX from the Wireless Receivers (RF) folder of the Device
Library and drop it in the upper pane of the System Views. The System Views upper
pane displays the TPS-RFGWX device icon below the PRO2 graphic.
Drag the STX-1700CXP from the Touchpanels (Wireless | Wireless Two-Way)
folder of the Device Library and drop it on the TPS-RFGWX symbol in System
Views.
The PRO2 system tree displays the STX-1700CXP (Cresnet) in Slot 9 with a default
Net ID of 03, the BB/DA-1700CW in Slot 9 with a default Net ID of 51, the
TPS-RFGWX gateway in Slot 9, with a default Net ID of 52, and the TPS-RFGWX
displays the touchpanel at the touchpanel's default RF ID location, "01," as shown in
the following graphic.
C2Net Device, Slot 9
Crestron STX-1700CXPW
Operations Guide - DOC. 6249A