Electrical Data (Hv8000 Pumps With Motors Only); Connections; Noise And Vibration Data - Edwards HV8000 VF Instruction Manual

Booster pumps
Table of Contents

Advertisement

2.7

Electrical data (HV8000 pumps with motors only)

For motor wiring information refer to the wiring diagram supplied in the motor terminal box. The dual voltage motors
can be configured to operate with either the high range or low range electrical supply.
Edwards endeavour to supply dual voltage motors preset to the highest of the selectable voltages.
For motor current information refer to the motor rating plate.
Ensure that the electrical installation of your HV8000 pump conforms with your local and national safety
requirements, refer to
Section
Table 6 - Nominal electrical data (refer to motor rating plate for details)
HV8000 Vertical flow
HV8000 Horizontal flow
HV8000 Vertical flow
HV8000 Horizontal flow
2.8

Connections

Process inlet/outlet
HV8000 pumps
Cooling-water inlet/outlet
2.9

Noise and vibration data

Note:
The noise and vibration data values given below are maximum values. The actual values will depend on the
installation and the operating conditions.
Noise level
Vibration level
*
The noise level was measured in accordance with ISO2151 and with the pump running at ultimate pressure.
Running at higher inlet pressures will increase the noise level.
The rotors are balanced to G2.5 and have ventilated end caps fitted.
© Edwards Limited 2014. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
3.8.
No of
Power
poles
A31103940
18.5 kW
2-pole 380/400 V 50 Hz, 230/460 V 60 Hz
A31104940
18.5 kW
2-pole 380/400 V 50 Hz, 230/460 V 60 Hz
A31103934
18.5 kW
2-pole
A31104934
18.5 kW
2-pole
Table 7 - Connections data
PN20/DN250 (ANSI 10 inch)
Rp 1/2 inch ISO 7-1 (1/2 inch BSP cylindrical internal thread)
Table 8 - Noise and vibration data
Voltage/Frequency
200 V 50 Hz, 200/380 V 60 Hz
200 V 50 Hz, 200/380 V 60 Hz
HV8000
82 dB(A)
4 mm s
0.16 inch s
A311-03-880 Issue A
Frame
Flange
size
type
160L
FF300
160L
FF300
160L
FF300
160L
FF300
*
-1
-1
Page 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents