System Errors
System Errors
Code
Type
Description
EB00
Rec-
Stop Button
ord
Pressed
Rec-
EC00
Setup
ord
Value(s)
Changed
EL00
Rec-
System
ord
Power On
EM00
Rec-
System
ord
Power Off
EMIX
Advi-
Pump Off
sory
ES00
Advi-
Factory
sory
Defaults
Communication Errors
NOTE: In some error codes listed below, a # symbol is shown as the last digit. This symbol represents the
applicable component number, which can vary. The unit's display will show the applicable number as the last
digit in the code. For example, the CAC# code listed in this table will be displayed as CAC1 if the affected
component is color change board 1, CAC2 for board 2, and so on.
Code
Type
Description
CA0X
Alarm
Comm. Error
ADM
CAC#
Alarm
Comm. Error
Color Change
#
CADX
Alarm
Comm. Error
Fluid Module
68
Problem
Record of a stop button
press.
Record of changing
setup variables.
Record of power cycle
(ON).
Record of power cycle
(OFF).
The pumps are not
powered and are
unable to move.
Record of defaults
being loaded.
Problem
System does not
detect the Advanced
Display Module
(ADM).
System does not
detect the Color
Change Module #.
System does not
see the Enhanced
Fluid Control Module
(EFCM).
Cause
Indicates system stop
key on ADM was
pressed.
Indicates date and time
when setup values
were changed.
Indicates date and
time when system was
started.
Indicates date and
time when system was
turned off.
Pump power was
turned off or an error
occurred.
Cause
This communication
error indicates that
the Network has lost
communication with
the Advanced Display
Module.
This communication
error indicates that
the network has lost
communication with
the Color Change
Module #.
This communication
error indicates that
the Network has lost
communication with
the EFCM.
Solution
n/a
n/a
n/a
n/a
Start pumps by
pressing pump start
key on Advanced
Display module.
n/a
Solution
Check CAN cable
connecting ADM to
the EFCM.
Check CAN cable
connections to
the Color Change
Module # and any
interconnected
modules.
Check CAN cables
connecting ADM to
the EFCM. Replace
Cable or EFCM as
necessary.