Fill Screen - Graco ProMix PD2K Electronic Operation

Proportioner
Hide thumbs Also See for ProMix PD2K Electronic:
Table of Contents

Advertisement

Fill Screen

The Fill screen displays the following information for
the pump assigned to the current color:
• Material. Select Color (A), Catalyst (B), or Solvent.
The pump animation at the top of the screen will
show the selected material. If solvent is selected,
enter the pump number in the box to the right.
• Flush Line (only for systems with color change).
Select this box if you want to flush the specified
material line with solvent. The system uses flush
sequence 1.
To prime the pumps and fill the lines, first read
Prime and Fill the System, page
1. Press the Edit softkey
for editing.
2. Select Color (A).
3. Enter the color number in the box to the right.
4. If the selected material is not already loaded,
press the Prime softkey
prime Color (A) into the selected pump through
the selected color valve and out the outlet dump
valve.
5. Press the Fill softkey
attempt to fill the Color (A) lines until the user
presses Stop
. Trigger the gun into a waste
container.
6. Repeat for Catalyst (B).
To flush the system (pump and fluid lines), see
Flush the System, page
To flush only the pump:
1. Press the Edit softkey
for editing.
2. Select Solvent.
3. Enter the pump number in the box to the right.
4. Press the Prime softkey
flush solvent through the selected pump and out
the dump valve.
332562B
25.
to open the screen
. The system will
. The system will
28.
to open the screen
. The system will
Figure 20 Fill Screen, Color (A) Selected
Figure 21 Fill Screen, Solvent Selected
Run Mode Screens