System Errors
Pressure Errors
NOTE: In some error codes listed below, a # symbol is shown as the last digit. This symbol represents the
applicable component number, which can vary. The unit's display will show the applicable number as the
last digit in the code. For example, the P6F# code listed in this table will be displayed as P6F1 if the affected
component is pump 1, P6F2 for pump 2, and so on.
Code
Type
Description
F6F#
Alarm
Press.
Sens.
Removed
Inlet #
P1F#
Alarm
Pressure
Low Inlet
Pump #
P2F#
Devi-
Pressure
ation
Low Inlet
Pump #
P3D#
Devi-
Pressure
ation
High Outlet
Pump #
P3F#
Devi-
Pressure
ation
High Inlet
Pump #
P4D#
Alarm
Pressure
High Outlet
Pump #
P4F#
Alarm
Pressure
High Inlet
Pump #
Alarm
Press.
P6D#
Sens.
Removed
Outlet #
P9D#
Alarm
Press.
Sens.
Failed
Outlet #
66
Problem
No inlet pressure
transducer is detected
when the system is
expecting one.
The inlet pressure on
pump # is less than
the user-entered alarm
limit.
The inlet pressure on
pump # is less than the
user-entered deviation
limit.
The outlet pressure
on pump # is greater
than the user entered
deviation limit.
The inlet pressure
on pump # is greater
than the user-entered
deviation limit.
The outlet pressure on
pump # is greater than
the user entered alarm
limit.
The inlet pressure on
pump # is greater than
the user-entered alarm
limit.
No outlet pressure
transducer is detected
when the system is
expecting one.
Outlet pressure
transducer has failed.
Cause
Disconnected
transducer.
Disconnected
transducer.
Outlet pressure
transducer has failed or
the pressure is above
the readable range.
Solution
Verify transducer is
connected properly.
Replace if reconnecting
does not eliminate the
alarm.
Increase inlet pressure.
Increase inlet pressure.
Relieve system
pressure.
Decrease inlet
pressure.
Relieve system
pressure.
Decrease inlet
pressure.
Verify transducer is
connected properly.
Replace if reconnecting
does not eliminate the
alarm.
Relieve system
pressure. Verify
connections, or replace
if reconnecting does
not eliminate the alarm.
332562B