Pump Screen 2

Pump screen 2 sets the pressure transducer settings
for the pump.
Figure 45 Pump Screen 2, Default Settings Enabled
Figure 46 Pump Screen 2, Default Settings Disabled
332562B
Default Settings Selected
When the "Use Default Settings" box is selected,
default settings are used for the calibration values,
and the fields are grayed out.
Default Settings Not Selected
When the "Use Default Settings" box is not selected,
the following calibration values must be entered.
Invalid values will be over-ridden and the system will
automatically select the default settings.
• Inlet Offset Factor: This field is only used if Inlet
Pressure in
Pump Screen 1, page 48
Monitor; it is grayed out if set to Disabled. The
valid range is -01.20 to +01.20 mV/V.
• Inlet Sensitivity Factor: This field is only used if
Inlet Pressure in
Pump Screen 1, page 48
to Monitor; it is grayed out if set to Disabled. The
valid range is 18.80 to 21.20 mV/V.
• Outlet Offset Factor: The valid range is -01.20 to
+01.20 mV/V.
• Outlet Sensitivity Factor: The valid range is 18.80
to 21.20 mV/V.
Setup Mode Screens
is set to
is set
49