Pump Volume Check - Graco ProMix PD2K Electronic Operation

Proportioner
Hide thumbs Also See for ProMix PD2K Electronic:
Table of Contents

Advertisement

Calibration Checks

Pump Volume Check

1. Set the mix manifold to the SPRAY position.
2. The pump and lines must be primed with color or
catalyst before doing the Volume Check. See
Prime and Fill the System, page
3. If the display is on a Run Mode screen, press
to access setup screens.
4. Scroll to Calibrate in the menu bar.
5. Scroll to
Calibrate Screen 2, page
6. Press the soft key
to check.
NOTE: For maximum accuracy, use a gravimetric
(mass) method to determine the actual volumes
dispensed. Verify that the fluid line is filled and
at the proper pressure before checking. Air in
the line or pressure that is too high may cause
incorrect values.
58
25.
51.
for the pump you want
7. Press the Reset key
will reset to 0.
8. Trigger the gun into a graduated cylinder.
Dispense a minimum of 500cc of material.
9. The volume that the unit measured displays on
the screen.
10. Compare the amount on the screen to the
amount in the graduated cylinder.
NOTE: If the value is substantially different,
repeat the test. If the dispensed volume and
measured volume still do not match, check that
the A and B pump positions are not reversed.
NOTE: Stop triggering the gun and press
to cancel the test.
. The volume counter
332562B