Stall Test Pressure
Set the minimum stall test pressure. The setting
should be approximately 50 psi (0.35 MPa, 3.5 bar)
higher than the highest inlet pressure.
Pump Stall Test
Set the duration for the pump stall test. See
Calibrate Screen 1, page
Maximum Leak Rate
Enter the maximum allowable leak rate for a pump
stall test.
332562B
51.
Mix Fill Set Point
Set a higher pressure for use while mix filling.
This higher pressure decreases the time needed
to fill the gun. Once the gun is filled, the system
uses the recipe's target pressure setpoint (set on
Recipe Screen, page
45) for mixing.
The default value is 0. When set to 0, the system
ignores the Mix Fill Set Point and instead uses the
Non-Mix Pressure (set on
while mix filling.
Setup Mode Screens
System Screen 1, page
39)
41