Setup Mode Screens

Pump Screen 3

Pump screen 3 sets the pressure alarm limits for the
pump.
When Inlet Pressure in
set to Disabled, the inlet limit fields are grayed
out and only the outlet limit fields are active. See
Pressure Alarm and Deviation Limits, page
Figure 47 Pump Screen 3, Pressure Monitoring
Disabled
When Inlet Pressure in
set to Monitor, all fields are active. See
Pressure Alarm and Deviation Limits, page
50
Pump Screen 1, page 48
50.
Pump Screen 1, page 48
50.
is
Figure 48 Pump Screen 3, Pressure Monitoring
Enabled
Pressure Alarm and Deviation Limits
Inlet fields are only active if Inlet Pressure
in
Pump Screen 1, page 48
are grayed out if set to Disabled. Outlet fields are
active at all times.
• Alarm and Deviation ranges are 0-300 psi for
is
low pressure systems, and 0-1500 psi for high
pressure systems.
• Setting to 0 will disable the alarm. The Inlet Alarm
High and Outlet Alarm High cannot be disabled.
• Alarms and Deviations will display when the inlet
or outlet pressure drops below the low limit or
exceeds the high limit.
is set to Monitor; they