The higher the PIO mode, the shorter the cycle time. As the IDE cable
length increases, this reduced cycle time can lead to erratic operation.
The total IDE cable length must not exceed 18 inches. If two IDE drives
are connected, they must not be more than six inches apart.
Environmental Specifications
Characteristic
Temperature
Operating
Non-operating
Humidity
Operating
Non-operating
Altitude
Operating
Nonoperating
a
Vibration
(9465 system
Operating
Nonoperating
a
Shock
(9465 system
Operating
Nonoperating
a
These values are with solid state hard drives and NOT rotating media drives
b
Consistent with system level specifications. See your system manual if you have a system other than
the 9465.
1-6
Caution
Table Chapter 1 -1. Environmental Specifications
0° to 55° C (32° to 140° F)
-40° to 85°C (-40° to 185°F)
20% to 80% RH noncondensing
20% to 80% RH noncondensing
Sea level to 10,000 feet (3048 m)
Sea level to 50,000 feet (15240 m)
b
)
5 to 55Hz
0.006" peak to peak displacement
56-2000 Hz
1.0g maximum acceleration
5-55 Hz
0.006" peak to peak displacement
56-2000 Hz
2.5 g maximum acceleration
b
)
15g peak acceleration, 11 msec duration
30g peak acceleration, 11 msec duration
Specification