SECTION 7 − DYNASTY 210 DX OPERATION
7-1.

Dynasty 210 DX Controls

1
.
For all front panel switch pad controls:
press switch pad to turn on light and en-
able function.
.
Green on nameplate indicates a TIG
function, Gray indicates a Stick func-
tion.
1
Standby Button
Use to put machine into low power
consumption mode.
.
This button can also be used to clear
some errors. See Section 12-3.
2
Amperage Adjustment Control
Use amperage adjustment control control in
conjunction with applicable front panel func-
tion switch pads to change values for that
function.
.
A complete Parts List is available at www.MillerWelds.com
3
4
3
Memory Card Port And Indicator
This port is used to add features to the ma-
chine and update software to the boards
within the machine. Indicator is lit while card
is being accessed.
4
Volt Meter
Displays actual rectified average voltage
when voltage is present at the weld output
terminals. It is also used to display paramet-
er descriptions while in the menu.
5
Ammeter
Displays actual amperage while welding and
preset amperage while idle. It is also used to
display parameter selection options while in
the menu.
5
2
6
6
Amperage Control
Use this control in conjunction with the am-
perage adjustment control to set the aver-
age weld amperage or peak amperage if the
Pulser is active.