SECTION 11 − ADVANCED MENU FUNCTIONS

11-1. Accessing Tech Menu For Dynasty/Maxstar 210 Models

2
TECH
ARC
ERR
SLEP
STUC
OCV
COOL
MACH
SOFT
SERL
.
A complete Parts List is available at www.MillerWelds.com
3
4
MENU
T/CY
[ARC] [T/CY] Arc Timer: Monitors hours, minutes, and cycles of valid arc
LOG
on. To view, rotate amperage adjustment control. To reset, rotate amper-
age adjustment control until [RESET] [YES] is displayed. Press Menu
button to display [RESET] [Done]. Displays turn to [000] [000].
[ERR] [LOG] Error Log: Use to view last eight logged error events. Each
OFF
event may list multiple Error Codes. See Section 12-3.
[SLEP] Sleep Timer: Turns power off after the machine exceeds the pro-
grammed idle time without operation. Press the Standby button to turn power
OFF
on. To set or change time, rotate amperage adjustment control to desired time.
Timer range: 1, 5, 10, 20, 30, 45 minutes or one hour.
[STUC] Stick Stuck: Detects if the electrode is stuck or shorted to the
workpiece. Turns weld output off to aid in freeing the electrode. To turn on,
NORM
rotate amperage adjustment control. Not recommended for air carbon arc
or large diameter electrodes.
[OCV] Open Circuit Voltage: Allows user to select between Normal
AUTO
(NORM) and Low open circuit voltage. Low reduces open circuit voltage
to between 8 and 15 volts. To select, turn amperage adjustment control.
[COOL] Cooler Power (Optional): Selects between [OFF], [ON] (Non
RSET
CE models Only), and [AUTO]. [OFF] disables the power supply to the
receptacle. [ON] enables the power supply to the receptacle. [AUTO]
provides power to the receptacle when the TIG process is active.
[MACH] [RESET] Machine Reset: Resets all machine values back to
WARE
factory defaults. To reset, turn amperage adjustment control to [RESET]
[YES]. Then press Menu button. [RESET] [DONE] will be displayed
when the reset is complete and factory defaults have been restored.
[SOFT] [WARE] Software Number: Software number and revision will
NUM
be displayed.
[SERL] [NUM] Serial Number: If serial number displayed does not
match serial number of machine, see Section 12-3.
1
Menu Button
Press and hold Menu button for ap-
proximately four seconds to scroll
past User Menu to Tech Menu. Use
1
Menu button to cycle through
parameters that can be set.
2
Parameter Display
3
Setting Display
4
Amperage Adjustment Control
Rotate amperage adjustment con-
trol to adjust parameter setting.
.
Dynasty 210 shown, Maxstar
menus are the same. Menu
order may vary.
To exit tech menu, press and hold
menu button approximately one
second, or turn power off.
.
Settings in the Tech Menu are
global, meaning they may
pertain to all or some of the
process.
OM-270536 Page 57